You can find the data of the enable path and the ASP 5001 in this section.
4.1
1. Switchoff distance
The configurable binary outputs are provided at different terminals. Also observe the projecting manuals (see
section 1.2 Further support). The binary outputs have the following technical data:
•
I
A max
= 50 mA
•
U
A max
≤
U
E
•
T
A type
= 1 ms
4.2
ASP 5001
Terminal description X12
Terminal description X1
Pin
Designation
Function
Data
3
GND
Enable
High level
≥
12 V
High level< 8 V
I
E max
= 16 mA
U
E max
= 30 V
4
+ input
Safety-relevant data of the enable path
Acknowledgement
MTTF
D
DC
avg
Mission Time
Without feedback
system
377 years
60 %
20 years
With feedback system 377 years
90 %
20 years
Pin
Id.
Function
1
NC contact
(break contact
element)
Feedback system; must be integrated in the safety circuit of the
controller!
2
3
Relay coil 1 (+)
Controller
a)
a) For a UL-compliant application, the use of a 4 AT fuse in the 24 vdc power supply line is mandatory. The fuse must be approved
according to UL 248.
4
Relay coil 2 (-)
1
2
3
4