Electrical characteristics
STM32L100RC
44/104
DocID024995 Rev 4
6.3 Operating
conditions
6.3.1
General operating conditions
5.
A positive injection is induced by V
IN
> V
DD
while a negative injection is induced by V
IN
< V
SS
. I
INJ(PIN)
must never be
exceeded. Refer to
Table 9: Voltage characteristics
for the maximum allowed input voltage values.
6.
When several inputs are submitted to a current injection, the maximum
Σ
I
INJ(PIN)
is the absolute sum of the positive and
negative injected currents (instantaneous values).
Table 11. Thermal characteristics
Symbol
Ratings
Value
Unit
T
STG
Storage temperature range
–65 to +150
°C
T
J
Maximum junction temperature
150
°C
Table 12. General operating conditions
Symbol
Parameter
Conditions
Min
Max
Unit
f
HCLK
Internal AHB clock frequency
-
0
32
MHz
f
PCLK1
Internal APB1 clock frequency
-
0
32
f
PCLK2
Internal APB2 clock frequency
-
0
32
V
DD
Standard operating voltage
BOR detector disabled
1.65
3.6
V
BOR detector enabled, at
power on
1.8
3.6
BOR detector disabled, after
power on
1.65
3.6
V
DDA
(1)
Analog operating voltage
(ADC and DAC not used)
Must be the same voltage as
V
DD
(2)
1.65
3.6
V
Analog operating voltage
(ADC or DAC used)
1.8
3.6
V
IN
I/O input voltage
FT pins; 2.0 V
≤
V
DD
-0.3
5.5
(3)
V
FT pins; V
DD
<
2.0 V
-0.3
5.25
(3)
BOOT0 pin
0
5.5
Any other pin
-0.3
V
DD
+0.3
P
D
Power dissipation at
T
A
= 85 °C for suffix 6 or TA=105°C for
suffix 7
(4)
LQFP64 package
-
444
mW
T
A
Ambient temperature for 6 suffix version Maximum power dissipation
(5)
–40
85
°C
Ambient temperature for 7 suffix version Maximum power dissipation
–40
105
T
J
Junction temperature range
6 suffix version
–40
105
°C
7 suffix version
–40
110
1.
When the ADC is used, refer to
.
微可Vicor——值得信赖的元器件供应商
http://www.vicor.top/
021-31660491
微可Vicor——值得信赖的元器件供应商
http://www.vicor.top/
021-31660491