15
Jumpers and solder bridges
15.1
Jumpers
The jumper functions and their default status are described in
Table 21.
Jumper configuration
Reference
Jumper
Function
Comment
JP1
[1-2]
VIN connected to USBPD
Connect buck
‑
boost VIN to the V
BUS
from USB Type-
C
®
when the double switch is activated
OFF
VIN free for use
Enable the use of an external power supply as
buck
‑
boost VIN input voltage
[2-3]
VIN connected to GND
Deactivate buck
‑
boost function, VIN not accessible
JP4
ON
3V3 connected to VDD
3.3 V powers VDD. It is impossible to measure the
current.
OFF
3V3 not connected to
VDD
VDD is not powered. Add an ammeter to measure the
current.
JP5
STLK
5 V is supplied from USB
STLK CN3
•
5 V (+/- 5 %),
•
700 mA embedded overcurrent protection
•
Up to 500 mA capable
CHGR
5 V is supplied from USB
STLK CN3
•
5 V (+/- 5 %)
•
No embedded current protection
•
Up to 1.5 A current recommended
USBC
5 V is supplied from
LTC3114-1 5 V converter
(Power source connected
to USB Type-C
®
CN2
connector)
•
5 V (+/- 3 %)
•
Embedded selectable current protection (Up to
950 mA on 5 V, up to 1.5 A on USB Type-C
®
V
BUS
)
•
USB Type-C
®
V
BUS
nominal voltage from 5 V to
15 V
E5V
5 V is supplied from 5V_I
pin of CN9 extension
connector
•
5 V (+/- 5 %)
•
No embedded current protection
•
Up to 1.5 A current recommended
JP6
OFF
STLINK-V3E Active state STLINK-V3E detects USBSTLK plug on CN3
ON
STLINK-V3E Reset state
Set STLINK-V3E in Reset mode (All input/outputs in
high impedance)
JP7
ON
T_NRST (PA6)
STLINK-V3E output reset connected to T_NRST of
STM32
OFF
STLINK-V3E output reset isolated from T_NRST of
STM32
1. The default setting is in bold.
2. JP6 and JP7 must not be ON together
UM2577
Jumpers and solder bridges
UM2577
-
Rev 2
page 40/54