STM 1701054 Скачать руководство пользователя страница 2

 

of

   

1

The Manual of Oil Pump 

Read the following precautions and instructions before you begin assembly or using.   

Failure to comply with these instructions could result in personal injury or property 

damage. Keep these instructions in a convenient location for future reference. 

Important Note 

The guarantee will be void if the pump has been altered in any way. 

Profile 

Oil pumps can be used to transfer lubrication oil, waste oil and antifreeze liquids. 

This manual is applicable to the following pump only, please confirm your pump is included. 

Specification 

Item No. 

1701054 

1701055 

1701056 

Compression Ratio 

5:1 

Operating Pressure(bar/psi) 

5-8 / 70-115

Max. fluid Pressure (bar/psi) 

40/580 

Air Consumption (L/min M3/hour) 

180/6.5 

Capacity (L/min Gallon/min) 

25/6.6 

Tube Diameter (mm/inch) 

42/1.65 

Suction Tube Length (mm/inch) 

270/10.6, Wall installed / 

Extension transfer

730/28.7

940/37

Air Inlet Connection 

1/4” quick plug / 1/4” NPT female 

Oil delivery Connection 

Male 3/4” 

Max. Viscosity Oil Delivered 

SAE 240 

Temperature Oil Delivered 

-10~5

0℃

Noise Level (dB) 

82 

Содержание 1701054

Страница 1: ...Manual 5 1 High Ratio Oil Pump...

Страница 2: ...ste oil and antifreeze liquids This manual is applicable to the following pump only please confirm your pump is included Specification Item No 1701054 1701055 1701056 Compression Ratio 5 1 Operating P...

Страница 3: ...of 7 2 5 1 Series Oil Pump Exploded View...

Страница 4: ...shooting Problem Possible Causes Solutions The pump continues to operate after the gun trigger has been released 1 The is a oil leak at some point of the circuit 2 Valve sets part No 24 and 208 209 21...

Страница 5: ...are attached with compressed air treatment equipment please empty the water retained in the reservoir of the filter purger frequently For the pumps that are attached with a lubricator please pay close...

Страница 6: ...to Use Directly Fitted Pump into the Drum 1 Insert the suction tube of pump into the drum and secure with ring nut suitable for commercial drums with 57 diameter hole and threading 2 BSP 2 Fit a oil d...

Страница 7: ...ls at about 1200mm height appropriate for the tank s dimensions Make sure that the wall is solid and thick enough for the dowels Do not interfere with hydraulic tubes or electric lines 2 Secure the pu...

Страница 8: ...r extension elements See the examples given above 2 Example of possible application to pump with drum or rigid suction tube for obtaining personalized lengths according to needs 3 Remove filter and fo...

Отзывы: