background image

 
 

 
 

STL Reference: 

Date: 

 

Revision: 

MWS-Ex-DC 

July 2020 

 

IOM-MWS-iss0 

Document: Installation and Operations Manual  

P a g e

 | 

4

 

 

a.  Detection Range:

 

 

The sensor sensitivity 
can be adjusted by 
selecting a combination 
of 4 DIP switches to 
suit the application. 

(50% is the factory default 
– switches 1,2 and 4 ON, 
switch 3 OFF)

 

 

 

 

b.  Time Delay 

The ON-time of the light, after the person/object leaves the 
area, can be selected with a combination of 4 DIP 
switches.  

(5 seconds 

‘Walk test mode’ is the factory default – all switches 

ON)

 

 
 
 
 
 
 

 

c.  Daylight Threshold 

The threshold can be selected with a combination of 4 DIP 
switches. The light will not switch ON if the ambient lux 
level exceeds the programmed daylight threshold. 

(Please note that the ambient lux level refers to the amount of light reaching 

the sensor internally)

If the daylight sensor is disabled, the sensor will only 
operate when movement is detected. 

(Daylight sensor disabled is the factory default 

– all switches ON)

 

 
 

 

 

Contact 

 

 

STL International Ltd 

Hill Farm, Linton Hill 
Maidstone, Kent 
ME17 4AL 
United Kingdom 

 

Tel  

: +44 (0)1622 749633 

Fax 

: +44 (0)1622 746800 

eMail 

[email protected] 

Web 

www.stl-int.co.uk

 

 