background image

Connecting Your System

 

 

D. INPUT/OUTPUT CONNECTIONS

 

The STK VP240D/VP120D PA amplifier is designed to be as versatile as possible. The following descriptions of the 
input and output connections are designed to help you maximize the unit's potential. 
 

1. XLR Input Jacks 

Electronically  balanced  inputs 
accepts a standard XLR male 
connector. 
Pin1=ground,   
Pin2=hot or po). 
Pin3=cold or negative(-). 

 

1. GROUND
    (shield)
2. HOT +

3. COLD -

1

2

3

Tip PO)

Sleeve GROUND(shield)

 

2. Barrier Strip Connector 

 

Accept  balanced  line  level 
signal  by  strip  wire  joints,  the 
“+”  terminal=Hot  or  Positive, 

-

” terminal=Cold or Negative, 

“ ” =Circuit Ground. 

 

3. Speaker Outputs

 

Speaker connections are 5 block screw terminal connectors for Low and High impedance. 
Each impedance method provides a safe and reliable connection capable of transferring high power signals if properly 
connected. To avoid ANY possible shock hazard, the power amplifier should be disconnected from the AC, DC 
power source before making any connections. When connecting your speakers using each method, be sure to 
pay close attention to proper polarity. Although connecting your speaker systems out of phase using the wrong 
polarity will not damage your speakers, it will affect the quality of sound. When using bare wire connections, 
be sure that your connections are "clean." If any strands of wire from one connector are allowed to touch the 
adjacent connector, damage to your amplifier and sound system could occur. 

 

FIGURE : Low & High Impedance Output 

 

 

Also be sure above total impedance is less than rated impedance. 
 

NOTE

 

An amplifiers RMS voltage at rated output may also be determined by   

measuring with an RMS voltmeter or calculated using the following formula.

 

FORMULA : V(RMS) = 

Z X 

P

 

where      V = RMS voltage in volts 

                Z = amp rated load impedance in ohms 

                p = Power rating in walt (RMS)

 

EXAMPLE 1 : Using the same 240 watt @ 4 ohms amplifier in the preceding example, substitute into the formula as follow. 

 

              V (RMS) = 

Z X 

              V (RMS) = 

4 X 

240 

              V (RMS) = 31 

              When rounded off, the formula indicates an RMS voltage rating of 31 volts.

 

EXAMPLE 2 : Using the Load impedance at 100V at 240 Watts

 

              V (RMS)    = 

Z X

              Z                =    V X V / P 

              Z                = 100²/240 = 41.6 ohm (100V Terminal Minimum Load Impedance)

 

 

Output
Cable

Содержание VP-120D

Страница 1: ...VP 240D VP 120D Public Adress Power Amplifier OWNER S MANUAL ENGLISH...

Страница 2: ...ality components such as an ultra low noise 5532 OP amplifiers and powerful 3 stage bi polar output devices with reliable quality power filter capacitors Amplifier s protection provided by short circu...

Страница 3: ...te outlet Do not defeat the safety purpose of the polarized plug 9 Grounding If the appliance is equipped with a 3 wire grounding type plug a plug having a third grounding pin this plug will only fit...

Страница 4: ...pro com STK LIMITED 1 YEAR WARRANTY STK electronics are warranted to be free from defects in materials and workmanship under normal use for a period of 1 year from date of original purchase During tha...

Страница 5: ...ing post connector Connect the 24V DC Battery 100A Type source to these terminal Red connects to battery s positive and Black connects to battery s negative side The internal DC Fuse is equipped with...

Страница 6: ...it and represents a dangerous safety hazard 3 Line Voltage Operate from AC mains not more than 5 above or below the specified line voltage Failure to comply may invalidate your warranty 4 Pre Connect...

Страница 7: ...en connecting your speakers using each method be sure to pay close attention to proper polarity Although connecting your speaker systems out of phase using the wrong polarity will not damage your spea...

Страница 8: ...status of various operating conditions Knowing what these indicator LEDs are telling you will help you to use your STK amplifier 1 Level Meter A level meter for main stage indicates that your signal l...

Страница 9: ...9 Block Diagram...

Страница 10: ...BALANCED Cooling 2 STEP FAN COOLING Dimension W x H x D Net 483 x 88 x 295 mm Shipping 400 x 550 x190 mm Weight Net 37 Ibs 16 8Kg Shipping 39 68 Ibs 18Kg Power Consumption 1 3 POWER 130Watts VP120D 2...

Страница 11: ...11 Notes...

Страница 12: ...12 Owner s Manual for The STK VP240D VP120D High Impedance Power Amplifier Printed In Korea APR 2010 STK Professional Audio VP240D VP120D...