13
Installation Cont.
Gas Connection
The appliance’s gas inlet fitting is a 1/2” male threaded conic gas type in accordance with the ISO 7-1
standards.
• When making the gas connection Fig. 8, it is critical to place the gasket (Fig. 8, A) in between the inlet pipe
(Fig. 8, C) and the elbow (Fig. 8, B), to ensure a gastight seal.
• Ensure that you tighten the nut on the inlet pipe straight to avoid a gas leak.
• DO NOT USE TEFLON TAPE OR OTHER GAS THREAD SEALENT
Fig. 8
Fig. 8
A
B
C
For NG or LPG you need to install the regulator (Fig. 9) supplied with the appliance. The regulator has a test
point to enable an authorised licenced plumber/gasfitter to check for gas leaks after the cooktops installation.
Fig. 9
Screw LPG setting
Screw NG setting
Gas pressure test point
MODEL: SGGC77 | PRODUCT CODE: 6014
9