Wing Actuators do not function. 

Check voltage at Wing Actuator. If the 

voltage is present, the Wing Actuator has 

failed. 

 

If there is no Actuator voltage, check for open 

Actuator fuse (F1 15 AMP).  See fuse legend 

figure 5. 

 

The Arrow Board LED intensity is low 

 

Probably the solar window at the rear of the 

Arrow Board is dirty not allowing the photo 

sensor to operate at full intensity.  

 

                                                                          Table 1 TROUBLE SHOOTING GUIDE 

              

 

 

 

 

                                                                         Figure 5     FUSE LEGEND 

Содержание TC12-4884

Страница 1: ...1 OCT 30 2020 STINSON OWL LITE ARROW BOARD MODEL NO TC12 4884 USER MANUAL ...

Страница 2: ...UBLESHOOTING 8 SPECIFICATIONS 10 SPARE PARTS 11 Figure 1 INSTALLATION ELECTRICAL 4 Figure 2 INSTALLATION CABLES 6 Figure 3 TERMINAL BLOCK WIRING 7 Figure 4 CAB CONTROLLER 8 Figure 5 FUSE LEGEND 9 Figure 6 OUTLINE DWG 11 Figure 7 BOM 14 Figure 8 INTERCONNECT DWG 15 Table 1 TROUBLE SHOOTING GUIDE 9 ...

Страница 3: ...ertical position A Cab Controller and connecting cable are typically supplied Standard cable lengths are 35 ft For custom cable lengths please contact Stinson Customer Service Custom racks are available that allow the Arrow Board to mount horizontally To deploy the Arrow board in the vertical position a switch on the Cab Controller operates an actuator lifting the Arrow Board to the vertical posit...

Страница 4: ...LATION The electrical installation is shown in figure 1 The fuse shall be physically located at the Battery terminal and rated at 15 AMP A 10 AWG cable is required to power the Arrow Board Figure 1 INSTALLATION ELECTRICAL ...

Страница 5: ...5 OCT 30 2020 ...

Страница 6: ...6 OCT 30 2020 Figure 2 INSTALLATION CABLES ...

Страница 7: ...ill flash approximately 40 50 times per second The left and right LEDs and actuators can now be deployed by turning the left and right toggle switches to the UP or ON position To de activate the Arrow Board turn the bar switch to the OFF position The wings will return to the extended position and all LEDs on the Arrow Board will turn off There is an option for an auxiliary or beacon switch See Sti...

Страница 8: ...ircuits in the Arrow Board There are LED indicators that will illuminate under the following Conditions 1 A short circuit in the Left Arrow Right Arrow or Bar will open F4 F5 F6 2 A wing Actuator failure or short circuit will open F1 Under these conditions LED 5 will illuminate indicating fuse F1 has failed or is open 3 F3 is not employed In the case of fuse failure attempt to find short location ...

Страница 9: ... has failed If there is no Actuator voltage check for open Actuator fuse F1 15 AMP See fuse legend figure 5 The Arrow Board LED intensity is low Probably the solar window at the rear of the Arrow Board is dirty not allowing the photo sensor to operate at full intensity Table 1 TROUBLE SHOOTING GUIDE Figure 5 FUSE LEGEND ...

Страница 10: ... 1 5 AMPS F4 BAR LEDS LED 2 5 AMPS F5 ARROW LEFT LEDS LED 3 5 AMPS SPECIFICATIONS See Stinson Customer Service for specification details 1 800 561 6639 ELECTRICAL Maximum Peak Current Draw with Bar and One Arrow Flashing 3 0 Amps Average Current Draw with Bar and One Arrow Flashing 1 5 Amps MECHANICAL Weight 160 Lbs 73 5 kg Dimensions See Figure 6 ...

Страница 11: ... OCT 30 2020 Figure 6 OUTLINE DWG SPARE PARTS All major components can be replaced See Stinson Customer Service for spare part service 1 800 561 6639 Please see BOM on fig 7 for complete parts description ...

Страница 12: ...12 OCT 30 2020 ...

Страница 13: ...13 OCT 30 2020 ...

Страница 14: ...14 OCT 30 2020 Figure 7 BOM ...

Страница 15: ...15 OCT 30 2020 Figure 8 INTERCONNECT DWG ...

Страница 16: ...eturn All defective parts replaced under this warranty shall become property of STINSON If as claimed defect cannot be identified or reproduced in service the purchaser will be held responsible for the costs of replacement or remanufactured parts STINSON shall not be responsible for the transportation or mileage costs associated with repair or replacement of warranted products or parts The costs o...

Страница 17: ...nada L4K 1P2 Ph 905 669 2360 Fax 905 669 3537 Company Address Phone Fax Product Serial Date Purchased 130 Creditstone Road Concord Ontario Canada L4K 1P2 Ph 905 669 2360 Fax 905 669 3537 Company Address Phone Fax Product Serial Date Purchased Environmental ...

Страница 18: ...18 OCT 30 2020 40 C 50 C Operational 40 ...

Отзывы: