Stingray SV160 Series Скачать руководство пользователя страница 3

(3)

 

Figure 1

Typical installation. Valve must be 

installed with check valves.

Figure 2

Typical  recirculating installation. Valve 

must be installed with check valves.

Typical Installation 

Figure 1

When installed at or near the water heater and 

without a recirculation system:
Install the valve as shown in 

Figure 1

 with the mixing 

valve positioned below the hot water tank or heater.  

If this is not possible, pipe in a heat trap as shown.

Typical Installation 

Figure 2

When installed away from the water heater with a 

recirculating pump on the hot water supply line:

Note:

 If the valve is installed 20 feet or more from 

the water heater, it is important to recirculate the 

hot water supply to the mixing valve.
Install the mixing valve as shown in 

Figure 2

. The non-

circulated loop should be limited to 10 feet and must 

be flushed periodically.

GUARANTEE

Caution: 

The cold water line must be installed so 

that it is not affected by excessively hot ambient 

temperatures. Provisions shall be made to ther-

mally isolate the valve. Cold water pipe installed in 

the ceilings of boiler rooms or rooms that increase 

ambient temperature require a recirculating pump.  

Note:

 Gallon per minute ratings may vary de-

pending upon incoming water temperatures and 

pressures. Hot and cold water inlet pressures 

must be equal.

20

40

60

80 100 120

140

160

180

200

0

Cartridge Kit

Part Number

000833450

 

Thermometer

Part Number 

000667902

Maximum Inlet Pressure:

 125 PSI.

Recommended Supply Pressure: 

65 PSI.

Recommended Inlet Temperature:

 120

°

F.

*

*

When supplying 140°F or greater, additional outlet 

controls should be used.

Warning:

 This product contains chemicals known to the 

State of California to cause cancer and birth defects or 

other reproductive harm.

(Installer: California law requires that this warning be 

given to the consumer.)
For more information: www.oehha.org/prop65

Water

Heater

Storage

Tank

Check Valve (TYP.)

To Low 

Temperature

Fixtures

Series SV160

CW

A

B

Heat Trap

27” Drop

30

40

50

60

70 80

90

110

120

130

30

40

50

60

70 80

90

110

120

130

30

40

50

60

70 80

90

110

120

130

C

Water

Heater

Storage

Tank

Check Valve (TYP.)

To Low 

Temperature

Fixtures

Series SV160

CW

A

B

Heat Trap

27” Drop

30

40

50

60

70 80

90

110

120

130

30

40

50

60

70 80

90

110

120

130

30

40

50

60

70 80

90

110

120

130

C

Recirculating Pump

We guarantee the Stingray Systems Mixing 
Valve to be free from defects in workmanship 
and material, and, for a period of one year 