INSTRUCTION MANUAL

30

CLEANING AND STORAGE

KEEPING ELECTRODES CLEAN

   Ensure the device is completely turned off when removing the 

  electrodes from the treatment area.  

   Disconnect the electrodes from each lead wire and place on protective  

  liner supplied with the electrodes. 

   If electrodes are difficult to attach to the skin or the protective liner,    

  they may still be have more uses left prior to replacing. Try placing a    
  small drop of water on your cleaned fingertip and rub the water across  
  the entire gel part.  

   Place the electrode gel part, face up and let it air dry until the water is   

  absorbed and reconstituted. 

DO NOT

 wipe with a tissue or cloth.  

  If the electrodes are still not sticking completely to the treatment area   
  without any lifting, they 

MUST

 be replaced with new electrodes.

 

CAUTION

•  The life of electrodes is dependent on many factors including, but not  

  limited to, cleanliness of treatment area, oiliness of skin, amount of hair,  

  increased sweating, storage state, etc. 

•  If the electrodes are lifting or no longer stick to the treatment area, they 

MUST

    

  be replaced to avoid sudden shock or possible burns on any of the applied  

 

  electrodes, including the electrodes adhered correctly and completely.

•  Before applying self-adhesive electrodes, it is recommended to wash the area    

  with mild soap and water, completely drying the treatment area  

  before placement. 

•  NEVER

 remove the electrodes while the device is turned on. 

•  It is recommended to use the same size electrodes that are supplied with the    

  device for replacement electrodes. Electrodes smaller than those provided may    

  increase the chance of skin irritation or electrode burns.  Electrodes larger than    

  those provided may reduce the effect of stimulation, which could result in a false   

  need to increase the intensity resulting in electrode burns or shocks.

•  If needing new electrodes, replace with any StimChoice electrode that is  

  2” x 2” or larger in size.

•  Use of larger electrodes may reduce the effect of the stimulation.  

  Use of electrodes that are much smaller than the electrodes provided  

  with the StimChoice 4000 may increase the chance of skin irritation or electrode   

  burns occurring under the electrodes.

•  ALWAYS

 use electrodes that have been cleared for marketing by the FDA.

Содержание Choice 4000

Страница 1: ...TENS EMS INSTRUCTION MANUAL Model E400 6R For questions or concerns about your device please contact Technical Support at 800 871 7858 before returning your device or leaving a review...

Страница 2: ...s instruction manual is published by Compass Health Brands Compass Health Brands reserves the right to improve and amend this manual at any time without prior notice Amendments may however be publishe...

Страница 3: ...ONS AND WARNINGS 6 PACKAGE CONTENTS 13 KNOW YOUR DEVICE 14 SPECIFICATIONS 16 PROGRAM PARAMETERS 17 HOW TO CONTROL AND REDUCE YOUR PAIN 18 INSTRUCTIONS FOR USE 19 START THERAPY 20 ELECTRODE PLACEMENT G...

Страница 4: ...is highly effective in relieving pain TENS and EMS are now highly regularly recommended by doctors physiotherapists and pharmacists throughout the world MEDICAL BACKGROUND Explanation of Pain Pain is...

Страница 5: ...discuss this with your physician or therapist HOW EMS WORKS Electronic Muscle Stimulation EMS works by sending electronic pulses to the muscle needing treatment this causes the muscle to exercise pas...

Страница 6: ...to employ the classic training methods We recommend this mode for the regeneration and relaxation programs after a muscle training session HOW FITNESS MODE WORKS FOR MUSCLE STIMULATION EMS SUPPLEMENT...

Страница 7: ...is to be used to stimulate healthy muscles in order to improve and facilitate muscle performance Other benefits include With a significant improvement in various muscular qualities With no cardiovasc...

Страница 8: ...the device SAFETY SYMBOLS USED IN THIS MANUAL DANGER Indicates a potentially hazardous situation which if not avoided could result in death or serious injury WARNING Indicates a potentially hazardous...

Страница 9: ...ld cause electric shock burns electrical interference or death Together with a life supporting medical electronic device such as an artificial heart or lung or respirator In the presence of electronic...

Страница 10: ...ou suffer from any serious illness consult your physician in order to confirm that it is advisable for you to use this TENS EMS Stimulator WARNINGS AND PRECAUTIONS REGARDING THE ELECTRODES Apply elect...

Страница 11: ...Make sure the components are connected well and the electrodes are fixed on the part of the body you wish to treat or the therapy may not be effective DO NOT USE YOUR ELECTRODES THIS WAY Electrodes s...

Страница 12: ...electronic devices such as watches as this may damage the device DO NOT use near a cell phone as this may cause the stimulator to malfunction DO NOT bend or pull the end of the cord When pulling out t...

Страница 13: ...experience skin irritation or hypersensitivity due to the electrical stimulation or electrical conductive medium gel If you have suspected or diagnosed heart disease you should follow precautions rec...

Страница 14: ...INSTRUCTION MANUAL 13 PACKAGE CONTENTS StimChoice 4000 Electrodes 2 packs of 2 x 2 4 pk Quick Start Guide 3 AAA size batteries Instruction Manual 4 Lead Wire Storage Bag...

Страница 15: ...ower On Off Button 2 TENS EMS SPORT FITNESS Treatment Modes Buttons 3 Body Part Button 4 Treatment Program Button 5 Increase Decrease Output Ch A1 A2 6 Increase Decrease Output Ch B1 B2 7 Battery Comp...

Страница 16: ...2 per bar The left side controls A1 A2 The right side controls B1 B2 6 FRONT BODY PART Selected front body part for treatment indicated by the flashing body part 7 BACK BODY PART Selected back body p...

Страница 17: ...x 0 6 in H Weight 3 5 oz without batteries Operating Condition Temperature 41 F 104 F 5 C 40 C Relative Humidity 30 75 Atmosphere Pressure 700nPa 1060hPa Storage and Transportation Conditions Tempera...

Страница 18: ...frequency P3 Hans stimulation P4 Burst stimulation P5 Pulse modulation EMS P1 Intermittent stimulation 1 P2 Intermittent stimulation 2 P3 Stimulation with active rest SPORT P1 Endurance P2 Resistance...

Страница 19: ...unit off with pads still adhered to skin Rate your pain to check your progress 1 low to 30 high Intensity is based upon your level of comfort Stop the therapy session if pain has reduced or stopped If...

Страница 20: ...old and new batteries or different types of batteries WARNING If batteries leak and come into contact with the skin or eyes wash immediately with large amounts of water DISPOSAL OF BATTERY Depleted ba...

Страница 21: ...by the graphic on the left The StimChoice 4000 has 4 channels A1 A2 and B1 B2 Channels A1 A2 work together and B1 B2 work together although you can choose to use only one channel two electrodes Only i...

Страница 22: ...gram Press to select the stimulation program The device automatically defaults to the last treatment session treatment mode area program To change from the default to the desired Treatment Program pre...

Страница 23: ...more than two 2 seconds to switch off the device If there is no operation in the panel for three 3 minutes in the waiting state the device will switch off automatically STEP 9 Remove the Electrodes f...

Страница 24: ...sure electrodes completely adhere to the skin and are at least 2 apart but no more than 6 per channel CAUTION DO NOT treat both thighs legs calves shoulders arms hands wrists at the same time TENS NEC...

Страница 25: ...the groin In this case an electrode is applied to the main point of pain on the hip and a second in the direction that the pain is radiated LOWER BACK LUMBAR Attach both pairs of electrodes on the low...

Страница 26: ...e left to assist with increased strength LOWER ARM Place electrodes over the forearm as shown in the picture to the left to improve healthy muscles HAND Place electrodes on area of wrist hand as shown...

Страница 27: ...own to the left to assist with increased muscle strength LOWER LEG Place electrodes in any of the suggested positions shown to the left to assist in improving muscle fibers THIGH Place electrodes in a...

Страница 28: ...pezius BACK Upper Mid Lower Back ABS Abdominal Muscles ARM Biceps Triceps Hand Flexors Hand Extensors LEG Quadriceps Hamstrings Calf Muscles HIP Buttocks CAUTION DO NOT treat both thighs legs calves s...

Страница 29: ...irty Replace with new electrodes Electrodes do not stick to skin well Lead wire is old worn or damaged Replace with new lead wire Stimulation is uncomfortable Intensity is too high Decrease intensity...

Страница 30: ...Using electrodes on the same site every time Reposition the electrodes If at any time you feel pain or discomfort stop using immediately Electrodes are not adhered to the skin properly Ensure the elec...

Страница 31: ...nger stick to the treatment area they MUST be replaced to avoid sudden shock or possible burns on any of the applied electrodes including the electrodes adhered correctly and completely Before applyin...

Страница 32: ...n a resealable package Wrap lead wires and keep in the storage bag If device is not being used for long periods of time remove batteries from device before storing Place the batteries device electrode...

Страница 33: ...part is the electrode Refer to instruction manual SN Serial Number IP22 The first number 2 Protected against solid foreign objects of 12 5 mm and greater The second number Protected against vertically...

Страница 34: ...should be observed to verify that they are operating normally Portable RF communications equipment including peripherals such as antenna cables and external antennas should be used no closer than 30 c...

Страница 35: ...1 Group 1 The device uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISP...

Страница 36: ...mercial or hospital environment Surge IEC 61000 4 5 0 5kV 1 kV line s to lines 0 5kV 1 kV 2 kV line s to earth Not applicable Mains power quality should be that of a typical commercial or hospital env...

Страница 37: ...be used no closer to any part of device than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance d 1 2 P 15...

Страница 38: ...and land mobile radios amateur radio AM and FM radio broadcast and lV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters...

Страница 39: ...ER W 0 15 MHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 80 MHz to 2 7 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 SEPARATION DISTANCE ACCORDING TO FR...

Страница 40: ...y DO NOT extend the warranty period either for the device or for the replacement parts 3 The following is excluded under the warranty All damage which has arisen due to improper treatment e g nonobser...

Страница 41: ...THIS PAGE LEFT BLANK INTENTIONALLY...

Страница 42: ...THIS PAGE LEFT BLANK INTENTIONALLY...

Страница 43: ...THIS PAGE LEFT BLANK INTENTIONALLY...

Страница 44: ...Manufactured for Compass Health Brands 6753 Engle Rd Middleburg Heights OH 44130 www compasshealthbrands com 1 800 871 7858 2058 20 01 B 2020 Compass Health Brands Corp...

Отзывы: