background image

©  stilum GmbH, Gewerbegebiet Larsheck, 56271 Kleinmaischeid  •  Tel. +49 (0) 2689 92790-0  •  All rights and product modifications reserved

State: 15.02.2019 p. 2

Mounting instructions for horizontal bar „supra 2“ 

Item No.  55 1515 402

Legende

Erde, Grund

Ground

Beton

Concrete

Füllmaterial

Filling

700

500

450

450

Freie Fallhöhe = 

1370

Einbautiefe 450mm

D

E

F

C

1

2

3

4

B

A

3

2

1

5

C

D

4

6

7

8

A

B

Zust.

Änderung

Datum

Datum

Name

Name

Bearb.

Gepr.
Norm

A3

Bl.

Allgemein-

toleranzen

DIN 7168-m

Maßstab 1:20

 04.12.2014 Kistinger

 Supra 2

 0134-00-00-Supra 2

 0134-00-00

Fertigung

E

 

1.  Select the play equipment location in consideration of the required safety 

area (see Diagram 3: 2500x 3000mm). 

2.  Carry out excavation work for the foundation as shown in Diagram 2. After 

excavation, compress the foundation floor.

 

Note: 

The horizontal bar is built in on the play level. Pay attention to items 

marked „play level“ of play equipment! 

3.  Set up the three concrete foundations acc. to the dimensions indicated in 

Diagram 2 with central, horizontal reinforcement. 

4.  After a setting period of 10-14 days, depending on weather conditions and 

foundation size, clean the surface of the foundation.

5.  Place the pre-assemled sport equipment on the foundation and screw it with 

the heavy-duty dowels included in the delivery.

6.  Fill up and compress the holes between the foundation and the foundation 

hole with the excavation.

7.  Seal the whole minimum zone/safety area with the impact protection required 

for the fall heights indicated. Set up impact-absorbing playground surfacing 
according to EN 1176-1. 

Critical drop height: 1400mm

 

Recommended surface material: sand, wood chips, gravel,  
synth. fall protection

8.  Do not allow children to use the equipment before the installation has been 

finished. 

 

Reinforcement plan: 

Concrete foundation with reinforcement

Main foundation: BSt 500S 
Ever 4 stirrups Ø 8 mm lengthwise and cross 
Concrete cover h´= 3 cm
Concrete quality class C20/25

Diagram 3: Top view 

Extent of the minimum 

zone = safety area

Diagram 2: Side view with dimension details „supra 2“

Legende

Erde, Grund

Ground

Beton

Concrete

Füllmaterial

Filling

700

500

450

450

Freie Fallhöhe = 

1370

Einbautiefe 450mm

D

E

F

C

1

2

3

4

B

A

3

2

1

5

C

D

4

6

7

8

A

B

Zust.

Änderung

Datum

Datum

Name

Name

Bearb.

Gepr.
Norm

A3

Bl.

Allgemein-

toleranzen

DIN 7168-m

Maßstab 1:20

 04.12.2014 Kistinger

 Supra 2

 0134-00-00-Supra 2

 0134-00-00

Fertigung

E

 

2500

3000

OHNE SCHRIFTLICHE ZUSTIMMUNG DER KAISER GMBH DARF DIESE 

TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT, NOCH DRITTEN MITGETEILT ODER 

ZUGÄNGLICH GEMACHT WERDEN, NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER- 

WENDET WERDEN. ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT.

Oberflächen nach

DIN ISO 1302

Reihe 2

Zul. Abweichung

DIN 2768 - mH

1

 

supra 2 (450)

Benennung

Gepr.

Werkstoff

Blatt

Datum

Projekt

Gez.

Zuschnitt

Zeichnungsnummer

Rev

Änderung

Datum

1:20

A3

Gewicht

Name

Name

Draufsicht

2104-00-00

28.96

Maßstab

Simonis

02.05.18

 

 

A
Fallraum kleiner

14.02.19

ES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gewerbegebiet Larsheck

56271 Kleinmaischeid

Deutschland

Отзывы: