© stilum GmbH, Gewerbegebiet Larsheck, D-56271 Kleinmaischeid • Tel. +49 (0) 2689 92790-0 • All rights and product modifications reserved.
Mounting instructions for slide „quina“
Item-No. 51 3532 601
State: 04.06.2020 p. 2
Play level
Concrete
foundation
1. Select the location of the play equipment taking into account the required
minimum space (see diagram 4).
Note:
Due to possible overheating, do not place the slide surface southernly.
2. The impact area of a playground equipment with an enforced movement is
not allowed to overlap the impact area of other equipment.
According to DIN EN 1176-1, 4.2.8.5.2 shock-absorbing floors must be made
on the entire impact area of every equipment that cause forced movement.
3. Carry out excavation work for the foundations as shown in diagram 2. After
excavation compress the foundation floor.
Note:
The slide is installed at play level. Pay attention to items marked „play
level“ at play equipment!
4. Set up the concrete foundations according to diagram 2 with central, horizon-
tal reinforcement.
5. After a setting period of 10 – 14 days, depending on weather conditions and
foundation size, fill up and compress the holes between the foundation and
the foundation hole with excavation.
6. Clean the surface of the foundations and start with the installation of the play
equipment.
600
1000
400
1835
915
4317
450
1455
2630
400
1000
800
600
1291
OHNE SCHRIFTLICHE ZUSTIMMUNG DER KAISER GMBH DARF DIESE
TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT, NOCH DRITTEN MITGETEILT ODER
ZUGÄNGLICH GEMACHT WERDEN, NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER-
WENDET WERDEN. ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT.
1
quina
Benennung
Gepr.
Blatt
Datum
Projekt
Gez.
Zeichnungsnummer
1:25
A3
Name
Name
Fundamentplan
0608-00-00
Maßstab
Behnke
13.04.17
Gewerbegebiet Larsheck
56271 Kleinmaischeid
Deutschland
Beton
concrete
gewachsenes Erdreich
natural ground
Legende
stoßdämpfender Boden
shock-absorbing floor
SI
18.05.20
stoßdämpfender Boden
A
Datum
Änderung
Rev
Diagram 2: Foundation plan
Reinforcement plan:
Concrete foundation with reinforcement
Main foundation: BSt 500S
Stirrups Ø 8 mm lengthwise and cross
Concrete cover h´= 3 cm
Concrete quality class C20/25 – C25/30