background image

©  stilum GmbH, Gewerbegebiet Larsheck, 56271 Kleinmaischeid  •  Tel. +49 (0) 2689 92790-0  •  All rights and product modifications reserved.     

Mounting instructions for springrider „alva swing“ 

Item No. 51 3013 601

State: 08.12.2016 p. 2

 

100

600

50

450

520

Erde

Ground

Füllmaterial

Filling

Beton 

Concrete

Blatt:

Projekt:

Artikelnummer:

ZG-NR:

BENENNUNG:

OHNE SCHRIFTLICHE ZUSTIMMUNG DER C KAISER GMBH DARF DIESE TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT 

NOCH DRITTEN MITGETEILT ODER ZUGÄNGLICH GEMACHT WERDEN NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VERWENDET 

WERDEN. ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT.

FREIG:

GEPR:

GEZ

:

DATUM:

NAME:

WERKSTOFF



MAßSTAB:

OBERFLAECHEN NACH

DIN ISO 1302 REIHE 2

ZUL. ABWEICHUNG

DIN 2768 - mH

+0,3

-0,3

WERKSTUECKKANTEN

NACH DIN 6784

Gewerbegebiet Larsheck

56271 Kleinmaischeid

Deutschland

A3

1

0116-00-00

513012601

700x381x864

Fertigung:

Behnke

1x

Gewicht:

39060.29

Federbiene

Zust.

Änderung

Name

Abmaße:

Zuschnitt:

Fundamentplan

Datum

18.11.2016

100

600

50

450

520

Erde

Ground

Füllmaterial

Filling

Beton 

Concrete

Blatt:

Projekt:

Artikelnummer:

ZG-NR:

BENENNUNG:

OHNE SCHRIFTLICHE ZUSTIMMUNG DER C KAISER GMBH DARF DIESE TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT 

NOCH DRITTEN MITGETEILT ODER ZUGÄNGLICH GEMACHT WERDEN NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VERWENDET 

WERDEN. ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT.

FREIG:

GEPR:

GEZ

:

DATUM:

NAME:

WERKSTOFF



MAßSTAB:

OBERFLAECHEN NACH

DIN ISO 1302 REIHE 2

ZUL. ABWEICHUNG

DIN 2768 - mH

+0,3

-0,3

WERKSTUECKKANTEN

NACH DIN 6784

Gewerbegebiet Larsheck

56271 Kleinmaischeid

Deutschland

A3

1

0116-00-00

513012601

700x381x864

Fertigung:

Behnke

1x

Gewicht:

39060.29

Federbiene

Zust.

Änderung

Name

Abmaße:

Zuschnitt:

Fundamentplan

Datum

18.11.2016

Diagram 2: Side view with dimension details „alva“

Play level

Floor anchor

1.  Select the play equipment location in consideration of the required safety 

area (see Diagram 3: 3700 x 3400 mm). 

2.  The impact area of a playground equipment with an enforced movement is 

not allowed to overlap the impact area of other equipment. 
Regarding to DIN 1176 - 4.2.8.2.5, impact absorbing surfaces have to be put 
under the whole impact area of every equipment with an enforced movement.

3.  Carry out excavation work for the foundation anchor as shown in Diagram 2. 

After excavation, compress the foundation floor.

 

Note: 

The springrider is built in on the play level. Pay attention to items 

marked „game level“ of play equipment! 

4. 

Grout the foundation floor with concrete of quality class B25 up to a 

 

height of appr. 100 mm. 

5.  Insert the play equipment with foundation anchor into the concrete mass as 

shown in the diagram, so that the base plate is surrounded by a concrete 
thickness of at least 50 mm both above and below.

Reinforcement plan: 

Concrete foundation with reinforcement

Main foundation: BSt 500S

 

Ever 4 stirrups Ø 8 mm lengthwise and cross 
Concrete cover h´= 3 cm

Concrete quality class B25

Foundation

Содержание Alva swing

Страница 1: ...rsheck 56271 Kleinmaischeid Tel 49 0 2689 92790 0 All rights and product modifications reserved Mounting instructions for springrider alva swing Item No 51 3013 601 State 08 12 2016 p 1 Diagram 1 Overall view of the play equipment ...

Страница 2: ...E WERKSTOFF MAßSTAB 700x381x864 Fertigung Behnke Abmaße Zuschnitt Fundamentplan 18 11 2016 Diagram 2 Side view with dimension details alva Play level Floor anchor 1 Select the play equipment location in consideration of the required safety area see Diagram 3 3700 x 3400 mm 2 The impact area of a playground equipment with an enforced movement is not allowed to overlap the impact area of other equip...

Страница 3: ...onents made of stainless steel should not come with normal steel parts in contact Those steel parts may rub off and leave small steel particles in combination with moisture brown rust stains If such corrosion occur on stainless steel parts they are fine with an abrasive 240 grit to remove Please take care when transporting and setting up the fact that the components are made of stainless steel wit...

Страница 4: ... liquid cleaner e g on phosphoric acid and rinse off with clear water after a short application time During cleaning with mild abrasive components only wipe over stainless steel surface in polishing direction For heavily soiled surfaces polishes can be used e g for cleaning chrome on cars or for greasy and oily dirt alcoholic cleaning agents and solvents e g ethyl alcohol isopropyl alcohol or acet...

Отзывы: