6
Series 4141 Powerhead
Use the following procedure when refitting a DG or P screw in an existing thread:
– Place the screw in the hole and rotate it counterclockwise until it drops down slightly.
– Tighten the screw clockwise to the specified torque.
This procedure ensures that the screw engages properly in the existing thread and does not form a new thread
and weaken the assembly.
Note:
Power screwdriver settings for polymer:
– Plastoform screws
max. 600 rpm
– DG screws
max. 500 rpm