7 - Perform a spark test as indicated in
-
If the spark jumps:
the coil functions properly and
in the event of malfunction, verify that the cut-off
cable
(
13
) is not earthed.
- if the spark does not jump:
the coil is faulty and
must be replaced
8 - Refit the starter assembly
11.3. Replacing the coil
1 - Remove the starter assembly
.
2 - Disconnect the faston of the earth cable (
6
).
3 - Undo the screw (
9
) and the stud (
10
) and remove
the coil (
7
).
4 - Mount the new coil and regulate the air gap
according to the procedure indicated in points 4
and 5 in section
5 - Connect the faston of the earth cable (
6
).
6 - Refit the starter assembly
Tightening torques
1
Spark plug tightening torque
16-20 Nm
9
Coil fixing screw
8-12 Nm
10 Coil fixing stud
8-12 Nm
Technical information
Type of spark plug
GGP K7 RTC
Distance between electrodes
0,6-0,8 mm
Air gap/fan
0,35-0,45 mm
Special equipment
3
Tester for spark test
11. IGNITION