15

General safety notes

1.

The unit may only be connected to a power supply with voltage, current type and 
frequency matching the specification on the type plate! Never pull the power plug 
on the cord when unplugging it!

2.

Do not start operation of the unit if the power cord has been damaged or the
housing or the pressure hose shows sign of damage.

3.

Never connect the unit to compressed air!

4.

Operate only wirh pure brake fluid on glycol base (DOT 3, DOT 4, DOT 5.1).

Products containing mineral oil will destroy the unit!

5.

Before corrective maintenance, cleaning or repairs on electric devices, the user 
must ensure that the device is without current, i. e. switched off and the power plug 
pulled and the brake fluid has been drained from the unit.

6.

Repairs may only be performed by trained professionals with corresponding shop 
equipment.

7.

Improper repair or handling may lead to significant hazards to the user and may
damage the unit. Unintended use or improper operation of the unit will void the
liability for possible damages.

8.

A function and leakage check must be performed after the repair of the unit has 
been completed. It must be ensured herby that units for brake fluids are only 
operated with brake fluid on glycol base (DOT 3, DOT 4, DOT 5.1). The use of
brake fluids not recommended will lead to the destruction of the unit.

9.

Do not

put oil, or gasoline, soaked rags on the bleeder unit because of fire hazard.

GB

Содержание VARIO 5

Страница 1: ...Bedienungsanleitung Operating Instructions Mode d emploi Istruzioni per l uso Bremsen Service Ger te VARIO 5 VARIO 20 II VARIO 20 II PRO EG 30 60 EPC EG 30 60 EPC PRO...

Страница 2: ...ure that the device is without current i e switched off and the power plug pulled and the brake fluid has been drained from the unit 6 Repairs may only be performed by trained professionals with corre...

Страница 3: ...to fail It is recommended to use only brake fluid from its original container The hygroscopic properties of brake fluid cause it to draw and take in moisture from the air This dangerously reduces the...

Страница 4: ...eable nipple for suktion tube 4 Power cord 14 Coupler for suktion tube 5 ON OFF Switch 15 Connection low fluid indicator 6 Fuse 16 Container security barr 7 Low fluid level indicator 17 Wheel with cap...

Страница 5: ...m Electrical fuse M2 0A 5x20 mm Length of power cord ca 4 5 m Reg pressure range 0 3 5 bar adjustable Empty weight 23 kg Low fluid level shut off Yes Temp work area 0 C 45 C Pressure gage 0 6 bar 0 8...

Страница 6: ...p This procedure should be performed before every bleed job When the unit is well purged turn the unit off 5 and remove the quick coupling 3 from the nipple 8 The unit is now ready to use 6 Connect th...

Страница 7: ...the pressure regulator knob CW to the desired pressure Attention After changing the pressure adjustment of the bleeding unit readjust it back to the factory setting of 2 bar Feature Pre suction system...

Страница 8: ...ssure than 2 bar the pressure regulator must be reset to 2 bar When does the unit needs to be refilled After reaching a low level of brake fluid inside the container the unit will shut off the motor p...

Страница 9: ...properly with a wrench During bleeding process we recommend that the pedal be pressed a few times to flush the primary and secondary chambers of the master cylinder This flushes the dirt and air from...

Страница 10: ...23 Accessories Recovery Bottle Part No 3 0070 Reverse Bleeder Hose No 67 Part No 3 0069 Various adapters Please take note to our adapter application list www stierius com GB...

Страница 11: ...odo Stier Hydrotechnik GmbH Gutenbergstr 2 4 D 78727 Oberndorf Neckar Telefon 49 0 7423 3321 49 0 7423 4711 Technische Hotline Fax 49 0 7423 82422 Internet http www stierius com Email service stierius...

Отзывы: