Page 14 of 28
Room temperature compensation
The temperature may consist of
the room temperature,
or the outside temperature,
or the inlet temperature, the inlet temperature is measured with
a separate temperature sensor.
The purpose of this compensation is to prevent rapid temperature decreases in a room. The “Maximum
temperature compensation” is used to limit the room temperature corrected by the climate computer. Instead of
the room temperature you can also use the inlet or outside temperatures as the basis for temperature
compensation.
Room ventilation compensation
Bandwidth compensation
This setting is used to adjust the bandwidth to the current outside
temperature if the outside temperature exceeds the value setting.
Minimum ventilation compensation
The percentage by which the minimum ventilation should be corrected per
°C of change in outside temperature is set in the “Compens. minimum
ventilation” line (the compensation of the minimum ventilation is a relative
compensation).
Manual mode
You can also set the ventilation percentages for
Cleaning
and
Not in use
in
screen “1113 Manual control” in advance. The relevant settings are copied
as soon as the
Cleaning
or
Not in use
modes become effective for the
room.
Setting the room status to “
Cleaning
” and “
Not in use
” enables you to
manually enter the desired ventilation percentage when cleaning the room
at “Manual control” (percentage setting and calculated percentage are
equal). If the room has determined that the KL-61 is on manual operation,
the current status of the room is set to "cleaning" and the potentiometer
position of the KL-61 is taken over as the calculated manual operation (set
value and calculated value are not equal).
Note! The MANUAL CONTROL mode (cleaning) influences the alarm system, only use
this mode if there are NO ANIMALS in the room.
Room ventilation using growth curves
To ensure that the climate in the house develops along with the growth of
your animals, the climate computer has growth curves. Depending on the
current day number, the current setting is determined from the curve (if
the curve is
on
). A growth curve can consist of a maximum of 7
breakpoints.
Climate settings which are calculated in accordance with a curve are
preceded by the text “Growth curve”. To avoid having to continuously
adjust the curve settings to the animals' behaviour, you can increase or
decrease the calculated curve settings.
Growth curve temperature:
this enables you to increase or decrease the calculated room temperature.
Growth curve minimum:
this enables you to increase or decrease the minimum ventilation.
Growth curve maximum:
this enables you to increase or decrease the maximum ventilation.