iNSTALLATiON 

 

Specification

32

 | WPL-A  Premium 

www.stiebel-eltron.com

AA02

Integral heat pump control unit (IWS)

AA04

Inverter compressor

BF01

Flow sensor, heating

BP01

High pressure sensor (34 bar)

BP03

Low pressure sensor (16 bar)

BP05

High pressure switch (34 bar)

BT01

Heating flow temperature sensor - Pt1000

BT02

Heating return temperature sensor - Pt1000

BT30

Outdoor air temperature sensor - Pt1000

BT39

Expansion valve inlet temperature sensor - Pt1000

BT40

Hot gas temperature sensor - Pt1000

BT42

Frost protection temperature sensor - Pt1000

BT43

Condenser outlet temperature sensor - Pt1000

BT44

Evaporator inlet temperature sensor - Pt1000

BT46

Compressor intake temperature sensor - Pt1000

BT48

Oil sump temperature sensor - Pt1000

BT50

Hot gas temperature limiter

BT55

High limit safety cut-out temperature limiter NHZ

BT57

Recuperator inlet temperature sensor - Pt1000

EB01

Emergency/booster heater NHZ

EB03

Oil sump heater

FC05

Fan fuse 10 A 

KF21

Relay, booster heater NHZ1

KF22

Relay, booster heater NHZ2

MA01

Compressor motor

MA04

Expansion valve motor

MA07

Motor, diverter valve, defrost

MA16

Motor, valve, inverter cooling

MA20

Motor, heat pump fan

RF05

Split ferrite

RF06

Split ferrite

RF07

Split ferrite

XD01

External heat pump power supply terminal

XD02 

External NHZ terminal

XD03

External control terminal

XD05

External bus terminal

XD06

External ribbon heater terminal

XD28

Fan terminal

XE19

Terminal bracket support point

XE20

6-pole terminal box support point

XE21

Oscillation plate support point

XE22 

Floor plate support point

XE23

M4 terminal box support point

X11.1

3-pin IWS plug - power supply control

X11.2

2-pin IWS plug - compressor ON

X11.3

2-pin IWS plug - defrost valve

X11.4

2-pin IWS plug - oil sump heater

X11.5 

3-pin IWS plug - condensate ribbon heater

X11.6

3-pin IWS plug - NHZ 1

X11.7

3-pin IWS plug - NHZ 2

X11.8

3-pin IWS plug - power-OFF

X12.1

4-pin IWS Rast plug - fan PWM

X12.2 

12-pin IWS Rast plug - temperature sensor 1

X12.3

3-pin IWS Rast plug - BUS connection

X12.4 

7-pin IWS Rast plug - high/low pressure

X12.5 

5-pin IWS Rast plug - expansion valve

X12.7

6-pin IWS Rast plug - temperature sensor 2

X12.8

4-pin IWS Rast plug - temperature sensor 3

X12.10

5-pin IWS Rast plug - flow rate sensor

X12.11

4-pin IWS Rast plug - Modbus inverter

18.3  Application limit

18.3.1  Heating

  0

 10

 20

 30

 40

 50

 60

 70

 80

-30

-10

10

30

50

D

00000

81

79

0

X  Outside temperature [°C]

Y  Flow temperature [°C]

18.3.2  Cooling

  0

  5

 10

 15

 20

 25

 30

 35

 40

10

20

30

40

D

00000

81

79

0

X  Outside temperature [°C]

Y  Flow temperature [°C]

Содержание WPL-A 05 HK 230 Premium

Страница 1: ...OPERATION AND INSTALLATION Air source heat pump WPL A 05 HK 230 Premium WPL A 07 HK 230 Premium...

Страница 2: ...14 10 1 Transport 14 10 2 Heating water connection 14 10 3 Flow and return connection 15 10 4 Fitting the push fit connectors 15 10 5 Oxygen diffusion 16 10 6 Filling the heating system 16 10 7 Conden...

Страница 3: ...r gised for 2 minutes until the inverter capaci tors have discharged Never interrupt the power supply even out side the heating season The system s active frost protection is not guaranteed if the pow...

Страница 4: ...the system configuration the age of the system and the flow rates Confirmation of the specified output data can only be obtained if the test conducted for this purpose is also performed in accord ance...

Страница 5: ...ondenser transfers the heat to the heating circuit The refrigerant then expands again and the cycle restarts from the beginning At air temperatures below approx 7 C the humidity in the air condenses a...

Страница 6: ...e the dual mode temperature to 5 C After 1 to 2 years the dual mode temperature can be reset to e g 3 C Fault Cause Remedy There is a loss of pressure in the heating system Water drips from the safety...

Страница 7: ...B BE Remote control FET Remote control FE7 Ribbon heater HZB 1 Ribbon heater HZB 2 High limit safety cut out for area heating system STB FB Heating circuit pump UP 25 7 5 PCV T support SK 1 Wall mount...

Страница 8: ...air or other ventilation equipment In order to comply with the appliance s safety concept safety clearances to light wells must be observed Installation on foundation light well at ground level 1000 1...

Страница 9: ...liance and facilitate maintenance work D0000096921 f Never install the appliance in a recess Two sides of the ap pliance must remain exposed Material losses Please note that both the flow of outdoor a...

Страница 10: ...into the building to en sure that they are watertight The supply lines are all electric cables plus the flow and return lines To facilitate connection to the appliance we recommend using flexible supp...

Страница 11: ...ront and back Ensure you are using the correct brackets for the left and right hand slots respectively f Position the brackets so that the groove on the bracket is hooked into the appliance f Secure t...

Страница 12: ...ories with which the appliance was secured to the transport pallet D0000064201 f Hook two brackets respectively into the lateral slots on the front and back Ensure you are using the correct brackets f...

Страница 13: ...fer cylinder to ensure trouble free appliance operation The buffer cylinder provides hydraulic separation of the volume flows in the heat pump circuit and heating circuit and also serves as an energy...

Страница 14: ...nnected without removing the cover or side panels 10 1 Transport f When transporting the appliance be aware of its centre of gravity The centre of gravity is in the area where the compressor is locate...

Страница 15: ...17 0 5 mm Pipe diameter 28 mm 21 0 5 mm How the push fit connectors work The push fit connectors are equipped with a retainer with stain less steel serrations and an O ring for sealing The push fit co...

Страница 16: ...recommended in order to prevent corrosion Note Suitable appliances for water softening and desalinating as well as for filling and flushing heating systems can be obtained from trade suppliers Note Do...

Страница 17: ...to drain off 26_03_01_1868 1 1 Condensate drain f Observe chapter Electrical connection Ribbon heater f If the appliance is sited on foundations the condensate drips freely into the condensate drain p...

Страница 18: ...tion f Before working on the appliance isolate it from the power supply at the control panel Note The terminals are located in the terminal area of the ap pliance f Follow the instructions in the chap...

Страница 19: ...ation and the provision of high DHW temperatures Emergency mode If the heat pump shuts down due to a fault the heating output is covered by the electric emergency booster heater Heat up program only...

Страница 20: ...ated washer f Connect the following components to the heat pump manag er in accordance with the technical guides Circulation pump for the heat consumer side Outside temperature sensor Return sensor on...

Страница 21: ...safety cut out has tripped 26_03_01_1880 1 26_03_01_1880 1 Electric emergency booster heater f Remove the cause of the fault D0000035383 f Reset the high limit safety cut out by pressing the reset bu...

Страница 22: ...meter WP WATER FLOW RATE INFO HEAT PUMP PROCESS DATA f Compare the value with the minimum flow rate see chapter Specification Data table Minimum flow rate has been reached No further measures required...

Страница 23: ...you to adjust the heating curve cor rectly Fully open thermostatic or zone valves in a lead room e g living room and bathroom We do not recommend installing thermostatic or zone valves in the lead ro...

Страница 24: ...gh the emergency booster heater This will result in higher running costs f Switch the appliance off in the heat pump manager Parameter HEAT PUMP OFF COMMISSIONING SILENT MODE 13 4 Other settings f For...

Страница 25: ...ow and ice Remove any leaves or other foreign bodies from the evaporator fins periodically 17 Troubleshooting WARNING Electrocution f Before working on the appliance isolate it from the power supply a...

Страница 26: ...r If the appliance is operated in dual mode operation with an ex ternal second heat generator or as a module with a further heat pump set the DIP switch as shown WP Typ ON 1 2 3 4 D0000057055 DIP swit...

Страница 27: ...26_03_01_1880 1 Electric emergency booster heater f Remove the cause of the fault D0000035383 f Reset the high limit safety cut out by pressing the reset but ton f Check whether the heating water is...

Страница 28: ...270 1160 900 70 593 g01 g02 D0000034131 WPL A 05 HK 230 Premium WPL A 07 HK 230 Premium e01 Heating flow Type of connection Plug in connection Plug in connection Diameter mm 28 28 e02 Heating return T...

Страница 29: ...Installation Specification www stiebel eltron com WPL A Premium 29...

Страница 30: ...BF01 XE22 XD03 XD01 XD06 XD02 PE GND A B U V W MSD1 MSP3 L N PE 1 2 MP2 MSD8 XE19 PE N L Netzversorgung Inverter Abtauventil N Abtauventil L Verdichter ON PE Begleitheizung N Begleitheizung L lsumpfh...

Страница 31: ...1 N DHC 1 L DHC 2 N DHC 2 L 12 18V ND 4 20mA 12 18V HD 4 20mA CAN GND CAN L CAN H 12V Phase 4 Phase 3 Phase 2 Phase 1 12V Phase 4 Phase 3 Phase 2 Phase 1 Hei gastemperatur GND Hei gastemperatur Heizu...

Страница 32: ...5 Split ferrite RF06 Split ferrite RF07 Split ferrite XD01 External heat pump power supply terminal XD02 External NHZ terminal XD03 External control terminal XD05 External bus terminal XD06 External r...

Страница 33: ...4 6 8 10 12 25 20 15 10 5 0 5 10 15 20 2 3 4 5 7 8 9 10 D0000090274 X Outside temperature C 2 Max W65 4 Max W45 7 Min W65 9 Min W45 Y Heating output kW 3 Max W55 5 Max W35 8 Min W55 10 Min W35 DHW ou...

Страница 34: ...12 25 20 15 10 5 0 5 10 15 20 2 3 4 5 7 8 9 10 D0000090269 X Outside temperature C 2 Max W65 4 Max W45 7 Min W65 9 Min W45 Y Heating output kW 3 Max W55 5 Max W35 8 Min W55 10 Min W35 DHW output 0 2 4...

Страница 35: ...35 W18 partial load kW 3 37 4 94 Power consumption Power consumption at A7 W35 EN 14511 kW 0 61 0 61 Power consumption at A2 W35 EN 14511 kW 0 69 1 Power consumption at A 7 W35 EN 14511 kW 1 44 2 36 P...

Страница 36: ...48 148 IP rating IP 14B IP 14B Condenser material 1 4401 Cu 1 4401 Cu Dimensions Height mm 900 900 Width mm 1270 1270 Depth mm 593 593 Weights Weight kg 135 135 Connections Connection heating flow ret...

Страница 37: ...those subsidiaries Such guarantee is only grant ed if the subsidiary has issued its own terms of guarantee No other guarantee will be granted We shall not provide any guarantee for appliances acquire...

Страница 38: ...38 WPL A Premium www stiebel eltron com NOTES...

Страница 39: ...www stiebel eltron com WPL A Premium 39 NOTES...

Страница 40: ...TIEBEL ELTRON OY Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 7438 88 F...

Отзывы: