iNSTAllATiON
Specification
32
| SHP-A 220-300 Plus
www.stiebel-eltron.com
SHP-A 220 Plus
SHP-A 300 Plus
SHP-A 300 X
Plus
Power consumption
Average power consumption of heat pump (A20/W10-55)
kW
0.5
0.5
0.5
Average power consumption of heat pump (A15/W10-55)
kW
0.5
0.5
0.5
Average power consumption of heat pump (A7/W10-55)
kW
0.5
0.5
0.5
Max. heat pump power consumption (excl. start-up)
kW
0.65
0.65
0.65
Power consumption, emergency/booster heater
kW
1.5
1.5
1.5
Max. power consumption, heat pump + emergency/booster heater
kW
2.15
2.15
2.15
Energy data
DHW heating energy efficiency class (load profile), indoor air
A+ (L)
A+ (XL)
A+ (XL)
Electrical data
Power supply
1/N/PE 220-240 V 50/60 Hz 1/N/PE 220-240 V 50/60 Hz 1/N/PE 220-240 V 50/60 Hz
Permissible voltage range, external signal transmitter
~ 220-240 V 50/60 Hz
~ 220-240 V 50/60 Hz
~ 220-240 V 50/60 Hz
Max. operating current
A
8.54
8.54
8.54
Max. starting current
A
23.44
23.44
23.44
Fuse protection
A
C16
C16
C16
Sound emissions
Sound power level (EN 12102)
dB(A)
60
60
60
Average sound pressure level at 1 m distance, free field
dB(A)
45
45
45
Versions
IP rating
IP 24
IP 24
IP 24
Refrigerant
R134a
R134a
R134a
Refrigerant charge
kg
0.85
0.85
0.85
Global warming potential of the refrigerant (GWP100)
1430
1430
1430
CO
2
equivalent (CO
2
e)
t
1.216
1.216
1.216
Power cable length approx.
mm
2000
2000
2000
Dimensions
Height
mm
1501
1905
1905
Diameter
mm
690
690
690
Height when tilted
mm
1652
2026
2026
Height when tilted incl. packaging
mm
1895
2230
2230
Packing unit dimensions height/width/depth
mm
1740/740/740
2100/740/740
2100/740/740
Weights
Weight, empty
kg
120
135
156
Connections
Condensate connection
G 3/4 A
G 3/4 A
G 3/4 A
DHW circulation connection
G 1/2 A
G 1/2 A
G 1/2 A
Water connection
G 1 A
G 1 A
G 1 A
Heat exchanger connection
G 1
Values
Type of anode
Impressed current anode Impressed current anode Impressed current anode
Air flow rate
m³/h
550
550
550
Recommended number of users
≤ 4
≤ 6
≤ 6
The output data refers to new appliances with clean heat exchangers.
Nominal data to EN 16147 - Recirculation air heat pump
Further details
SHP-A 220 Plus
SHP-A 300 Plus
SHP-A 300 X
Plus
238633
238634
238635
Maximum altitude for installation
m
2000
2000
2000