INSTALLATION
Safety
INSTALLATION
6. Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
6.1 General safety instructions
We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
6.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
7. Appliance description
The sealed unvented (pressurised) appliance is only suitable for
undersink installation. The appliance is intended for heating cold
water and to supply one or several draw-off points.
The appliance may only be installed with pressure taps and in
conjunction with the safety valve supplied and a non-return valve
in the cold water supply line (see chapter "Installation / Appliance
description / Standard delivery").
The safety valve supplied protects the appliance against unaccept-
able excess pressure. The maximum allowed opening pressure
is 700 kPa.
If the water supply pressure exceeds 550 kPa, a pressure reducing
valve set to a maximum of 550 kPa, and compliant with AS 1357.2
and installed in accordance with AS 3500.4.2 must be fitted in the
installation.
The enamelled internal steel cylinder is equipped with a protective
anode. The protective anode protects the inner cylinder against
corrosion.
7.1 Standard delivery
The following are delivered with the appliance:
- Wall mounting bracket
- Safety valve G 1/2
- Reducer from R 3/4 male to G 1/2 female
8. Preparations
Water installation
The safety valve supplied and a non-return valve for the cold water
supply line are essential.
8.1 Installation site
!
Material losses
Install the appliance in a room free from the risk of frost.
!
Material losses
Mount the appliance on the wall. The wall must have a
sufficient load-bearing capacity.
!
Material losses
The appliance is only suitable for undersink installation.
The water connections of the appliance point upwards.
Note
Ensure that the appliance is freely accessible for main-
tenance work.
Always install the appliance vertically and near the draw-off point.
D
00000
50
30
1
Содержание SHC 10 AU
Страница 1: ...OPERATION AND INSTALLATION Sealed unvented pressurised small water heater SHC 10 AU SHC 15 AU ...
Страница 13: ...ENGLISH www stiebel eltron com SHC 10 AU SHC 15 AU 13 NOTES ...
Страница 14: ...14 SHC 10 AU SHC 15 AU www stiebel eltron com NOTES ...
Страница 15: ...ENGLISH www stiebel eltron com SHC 10 AU SHC 15 AU 15 NOTES ...