1. Operating instructions

 

 for the user and the qualified installer

The installation and use of electrical appliances
must be carried out with due caution in
order to avoid the risk of fire, electric shock
or injury. The equipment must only be used as
described in these instructions. Any use out-
side of the manufacturer recommendations
could lead to damage, fire, shock or injury.

Before using the appliance the instructions
should be read in their entirety and all
appropriate handling of the equipment must
be observed.

These instructions should be kept
safely and passed on to any future

owner.
In the event of any repair work, hand them
to the qualified installer for his attention.

Unit description

The RTF-Z digital controller enables individu-
al control of the heating mats. There are four
operating programmes.

When connected to the mains electrical supply
the controller switches on and regulates the
floor heating to a preset temperature. The
„heating operating symbol  “ is displayed.

After setting the time the controller auto-
matically switches to the timer programme.

By means of the self learning function of the
RTF Z, the start-time will be set directly into
the timer-program, from which the comfort
temperature will be achieved. Due to this, the
start of the heating-time will be before the
adjusted starting time.
The self-learning-function is activated by the
factory, if wished it can be deactivated within
the adjustment mode.

Switching ON & OFF

To switch off, press the 

M

 button and hold

for 3 seconds, the display will then show OFF.

1

M

ode - select an operating mode or

function by repeated pressing

2

Reset - restore the factory setting.
Briefly depress the flush-fitting push-
button with a non-conductive blunt object.

3

Increase the set value

4

Decrease the set value

5

Confirm the set value

6

Display

1

2

3

4

5

6

8966.02

8967.01

Functions

Heating operating
Time

P

Program selection

Timer programs

P1 = Program 1
P2 = Program 2
P3 = Program 3

Operating modes

7

Frost protection
Off-peak temperature
Comfort temperaure
Timer program

Days of the week

1-5 = Monday - Friday
6+7 = Sa Sunday

Start / end time in the timer program

S1 = 1st start time

E1 = 1st end time

S2 = 2nd start time

E2 = 2nd end time

S3 = 3rd start time

E3 = 3rd end time

Value indicator

Setpoint floor temperature
(Guide figure, e.g. 2.5 = approx.
25 °C) 

or

 time

Time segments of timer

    Comfort temperature
    Off-peak temperature

Factory settings

Timer program switching times

Floor temperatures of operating modes

Frost protection

1.0

=

^ approx. 10

Guide figure

°C

Off-peak temperature

1.8

=

^ approx. 18

Comfort temperature

2.5

=

^ approx. 25

Temperature setting limits

Max. Floor temperature

4.0

=

^ approx. 40

Min. Floor temperature

1.0

=

^ approx. 10

Displays

RTF-Z

Controller for Under-floor Heating Systems
Operation and installation instructions

18

55

82

21 

225 

01

To switch on again press and hold the 

M

button for 3 seconds. The controller will
switch on again to its most recent setting.

In the off position frost protection is

not

 provided.

Safety instructions

Do not operate the appliance

– in rooms which present fire or explosion

risks as a result of chemicals, dust, gases
or fumes;

– in the immediate vicinity of pipes or

containers which- carry or contain
combustible or potentially explosive
substances.

If a part of the appliance is damaged or has
fallen down or it was already defect/
malfanctioning, it may no be taken in to
operation.

287798

Содержание RTF-Z

Страница 1: ...h off press the M button and hold for 3 seconds the display will then show OFF 1 Mode select an operating mode or function by repeated pressing 2 Reset restore the factory setting Briefly depress the flush fitting push button with a non conductive blunt object 3 Increase the set value 4 Decrease the set value 5 Confirm the set value 6 Display 1 2 3 4 5 6 8966 02 8967 01 Functions Heating operating...

Страница 2: ... use is set In this operating mode the thermostat maintains the set value by intermittent operation of the floor temperature heating 1 6 12 18 24 0 2 5 Press the or push button to change the setpoint value Confirm by pressing the OK push button otherwise the previously set value will be restored after 20 seconds 1 3 4Timer program With the built in timer each weekday is allocated to a time program...

Страница 3: ...e or push button 6 12 18 24 0 Press the OK push button to switch to the 1st start time S1 of the selected program 6 12 18 24 0 P 1 S 1 06 00 Press the or push button to set the start time 15 minute steps Press the OK push button to switch to the 1st end time E1 of the selected program 6 12 18 24 0 P 1 E 1 09 00 Press the or push button to set the end time 15 minute steps Press the OK push button t...

Страница 4: ...ing capacity 16 2 A 230V Type RTF Z Range of adjustment ca 10 ºC 40 ºC Protection class ΙΙ acc this manual Switching difference 1 K H x W x D 85 x 81 5 x 44 5 mm Protection mode IP 30 after mounting Power reserve 4 days after 1h of operation Sensor characteristics value Temperature R kOhm U V 20 C 2 43 2 22 10 C 3 66 2 49 40 C 1 15 1 63 30 C 1 65 1 92 50 C 0 82 1 35 Approvals see rating plate 4 Gu...

Отзывы: