STIEBEL ELTRON PSH 20 Plus Скачать руководство пользователя страница 6

6

 | PSH  Plus 

www.stiebel-eltron-usa.com

INSTALLATION 

 

Cleaning, care and maintenance

Depending upon the system, the actual water temperatures at the 
tapping points may be lower than the set value.

 

WARNING Burns

There is a risk of scalding at outlet temperatures in 
excess of 109 °F (43 °C).
Setting the temperature above 125 °F (52 °C) is not rec-
ommended without the installation of a mixing valve.

ON/OFF indicator

The ON/OFF indicator illuminates when water is being heated.

5.1 

 Vacation and absence

f

If the appliance will not be used for a few days, set the tem-
perature knob to a position between the frost protection and 
energy saving settings.

f

If the appliance is not to be used for a longer period, set it to 
frost protection to conserve energy. If there is no risk of frost 
you may disconnect the appliance from the power supply.

f

To protect against Legionella, heat the water once 140 °F 
(60 °C) before using hot water again.

6.  Cleaning, care and maintenance

f

Have the electrical safety of the appliance and the func-
tion of the T&P relief valve regularly checked by a qualified 
technician.

f

Have the sacrificial anode initially checked by a qualified 
technician after the first year. The qualified technician should 
then determine the intervals at which it must be checked 
thereafter.

f

Never use abrasive or corrosive cleaning agents. A damp 
cloth is sufficient for cleaning the exterior of the appliance.

Scaling

f

Almost every type of water will deposit lime at high tem-
peratures. This settles inside the appliance and affects both 
the performance and service life. The heating elements must 
therefore be descaled from time to time. A qualified tech-
nician who knows the local water quality will tell you when 
the next service is due. Contact the water supplier or local 
plumbing inspector for additional information.

f

Check the taps/faucets regularly. You can remove lime scale 
deposits at the outlets using commercially available descal-
ing agents.

f

Regularly activate the T&P relief valve to prevent it from be-
coming blocked e.g. by lime scale deposits.

7. Troubleshooting

Problem

Cause

Remedy

The water does not heat 
up and the ON/OFF indi-
cator does not illuminate.

There is no power. 
 

Check the fuses/circuit 
breakers in your fuse 
box.

The water does not heat 
up sufficiently and the 
ON/OFF indicator is illu-
minated.
 

The temperature is set 
too low.

Select a higher tempera-
ture.

The appliance is heating, 
for example, after large 
amounts of DHW have 
been drawn.

Wait until the ON/OFF 
indicator goes out.  
 

The flow rate is low. 
 

The aerator in the tap or 
shower head is scaled up 
or contaminated.

Clean and/or descale the 
aerator or shower head. 

If you cannot remedy the fault, notify your qualified technician. To 
facilitate and speed up your inquiry, please provide the numbers 
from the type plate (000000 and 0000-000000):

Technical data

Datos técnicos

Données techniques

Made in EU

Hecho en EU

Fabriqué en EU

Volume:

Volumen:

Volume:

1 MPa / 145 PSI

Max. pressure:

Presión máxima:

Pression max:

PSH XX Plus

M-NO.:  000000
S-NO.:   0000-000000

Supply:

Alimentación:

Alimentation:

220-240 V AC, 60 Hz
SINGLE PHASE L-L ONLY

 

Power:

Potencia:

Puissance:

Standby loss:

Pérdida de calor:

Pertes en mode de veille:

 

1,5 MPa / 217 PSI

Testing pressure:

Presión de prueba:

Pression d'essai:

Содержание PSH 20 Plus

Страница 1: ...Std C22 2 No 110 Conforme a ANSI UL Std 174 Certi caci n con CAN CSA Std C22 2 No 110 Conforme la norme ANSI UL Std 174 Certi la norme CAN CSA Std C22 2 No 110 Tested and certi ed by WQA to NSF ANSI 3...

Страница 2: ...____________________ 9 12 Commissioning _______________________________________________9 12 1 Commissioning___________________________________________________ 9 12 2 Recommissioning___________________...

Страница 3: ...not provided 3 Check valve recommended not provided 4 Ball valve recommended not provided 5 Expansion tank required not provided 6 Vacuum breaker required not provided 7 Boiler drain valve recommended...

Страница 4: ...te Observation of these instructions and of instructions for any ac cessories used is also part of the correct use of this appliance WARNING To reduce the risk of excessive pressures and tempera tures...

Страница 5: ...ts DHW using an electric resistance element You can adjust the temperature using the temperature knob The water is heated automatically to the required temperature The internal steel cylinder is coate...

Страница 6: ...ts both the performance and service life The heating elements must therefore be descaled from time to time A quali ed tech nician who knows the local water quality will tell you when the next service...

Страница 7: ...er heater and the installation location Ensure that all fasteners used are of suf cient penetration depth into a suitable material to support the full weight of the appliance with an acceptable additi...

Страница 8: ...es to be drilled on the ply wood sheet see chapter 16 1 Dimensions and connections pg 11 f Drill a hole in the plywood to t the tee nuts into the back side of the sheet Thread the bolt and washer into...

Страница 9: ...breaker that disconnects all poles Before any work on the appliance disconnect all poles from the power supply Ensure that the appliance is grounded Material losses Observe the type plate The speci ed...

Страница 10: ...WARNING Electrocution Carry out all electrical connection and installation work in accordance with relevant regulations Before any work on the appliance disconnect all poles of the appliance from the...

Страница 11: ...PSH 30 Plus a10 Appliance Height 36 922 mm 48 1229mm a40 Appliance Diameter 20 510 mm 20 510 mm c01 Cold water inlet Male thread NPT male NPT male Rear clearance 3 95 mm 3 95 mm c06 DHW outlet Male th...

Страница 12: ...ller 4 ON OFF indicator 5 Heating element 6 Resistor 560 7 Anode 8 Cylinder 16 3 Heat up diagrams The heat up time depends on the cylinder capacity cold water inlet temperature and heating output Grap...

Страница 13: ...limits Temperature setting range 86 167 F 30 75 C 86 167 F 30 75 C Max permissible pressure 150 psi 1 0 MPa 150 psi 1 0 MPa Test pressure 217 psi 1 5 MPa 217 psi 1 5 MPa Max permissible temperature 20...

Страница 14: ...ket 315024 315024 11 Insulation ring 315038 315038 12 Union nut 315023 315023 13 Rubber bolt 268821 268821 14 Sacrificial anode 286093 286095 15 Anode gasket 286097 286097 16 Bushing pl 270957 270957...

Страница 15: ...aused by 1 any misuse or neglect of the Heater any accident to the Heater any alteration of the Heater or any other unintended use 2 acts of God and circumstances over which Manufacturer has no contro...

Страница 16: ...___________________________________ 23 12 1 Mise en service__________________________________________________23 12 2 Remise en service ______________________________________________23 13 Mise hors____...

Страница 17: ...ti retour recommand non fourni 4 Clapet bille recommand non fourni 5 Vase d expansion requis non fourni 6 Disjoncteur vide requis non fourni 7 Robinet de vidange de la chaudi re recommand non fourni 8...

Страница 18: ...ger par exemple dans une petite entreprise tant que son usage reste le m me Tout autre usage au del de l usage d crit sera jug inappropri L usage correct comprend galement le respect de ces directives...

Страница 19: ...ntie veuillez contacter Stiebel Eltron USA directement en composant le 800 582 8423 4 Description de l appareil L appareil chauffe l eau chaude sanitaire l aide d un l ment de r sistance lectrique Vou...

Страница 20: ...la dur e de vie Les l ments chauffants doivent donc tre d tartr s de temps en temps Un technicien quali connaissant la qualit de l eau locale vous indiquera le prochain service Contactez le four niss...

Страница 21: ...s utilis es ont une profondeur de p n tration suf sante dans un mat riau appropri pour supporter tout le poids de l appareil avec un facteur de s curit suppl mentaire acceptable Avant d installer l ap...

Страница 22: ...pitre 16 1 Dimensions et raccorde ments p 25 f Percez un trou dans le contreplaqu pour xer les crous de dans la partie arri re de la feuille En lez le boulon et la rondelle po dans l crou t en laissan...

Страница 23: ...h re Ne pas plonger dans l eau 11 2 Source de courant AVERTISSEMENT lectrocution Effectuez tous les travaux de raccordement et d instal lation lectriques conform ment aux r glementations en vigueur Ut...

Страница 24: ...ion Un vase d expansion n a pas t install Installez un vase d ex pansion en ligne avec l appareil voir sch ma de plomberie Touche de r initialisation coupure de s curit limite haute Si la coupure de s...

Страница 25: ...mag par un technicien quali 15 6 Remplacement du r gulateur limiteur combin D0000037142 2 1 1 Capteur du r gulateur 2 Capteur du limiteur f Ins rez le capteur du r gulateur et le capteur du limiteur d...

Страница 26: ...13 300 mm 11 265 mm 7 16 2 Sch ma de c blage L2 L1 2 1 3 4 5 6 7 8 1 Borne 2 D connexion de s curit limite haute 3 R gulateur de temp rature 4 Indicateur ON OFF 5 l ment chauffant 6 R sistance 560 7...

Страница 27: ...cation Plage de r glage de la temp rature 30 75 C 86 167 F 30 75 C 86 167 F Pression maximale admissible 1 0 MPa 150 psi 1 0 MPa 150 psi Test de pression 1 5 MPa 217 psi 1 5 MPa 217 psi Temp rature ma...

Страница 28: ...ide 315024 315024 11 Anneau d isolation 315038 315038 12 crou de raccordement 315023 315023 13 Boulon en caoutchouc 268821 268821 14 Anode sacrificielle 286093 286095 15 Joint d anode 286097 286097 16...

Страница 29: ...pression d eau irr guli re ou excessive ou dans le cas o le Chauffe eau serait aliment en eau non potable pour toute dur e que ce soit une installation incorrecte ou l utilisation de mat riaux incorre...

Страница 30: ...30 PSH Plus www stiebel eltron usa com NOTES...

Страница 31: ...www stiebel eltron usa com PSH Plus 31 NOTES...

Страница 32: ...h RP QX b c R XR b B db a bTaeT S TaaTdab Tc ST SXUXRPcX b cTRW X dTb Stand 8643 STIEBEL ELTRON Inc 17 West Street FTbc 7PcUXT S 0 01088 Tel 413 247 3380 Fax 413 247 3369 info stiebel eltron usa com...

Отзывы: