9
English
2. Installation instructions
for the professional
2.1 Regulations and Requirements
y
This fitting must be installed, commissioned and maintained only by an approved specialist in accordance with these instructions.
y
Area of application: open (pressureless) instantaneous water heaters.
y
Rated up to 0.6 MPa flow pressure - at pressures above 0.6 MPa, a pressure reducing valve must be fitted in the main pipe.
Rinse the cold water supply pipe thoroughly.
2.2 Installation of MAE
Insert the fitting with sealing ring (
7
) in the
washbasin and from below attach with U-
shaped washer (
8
), U-shaped thrust washer
(
9
) and clamping sleeve (
10
).
2.2.1 Water Connection
Connect the short connection hose marked
„blue“ (
4
,
×
blue ) to the angle valve - cold
water supply pipe.
Connect the two connection hoses to the
instantaneous water heater using union nuts
and seals.
Screw the connection hose (
5
,
Ø
blue) with
the downward-pointing arrow to the inlet
connector of the instantaneous water heater,
and connection hose (
6
,
×
red) with the up-
ward-pointing arrow to the outlet connector.
When fitting the connection hoses, note the
following
A
(see page 3):
– Do not bend hoses immediately after the
joint; leave a straight section of at least
15 mm;
– Do not kink hoses but ensure a minimum
curvature radius of 20 mm;
– Avoid distortion during fitting;
– Avoid tension during fitting;
– Twisting during fitting is not permitted.
2.3 Fitting the Drain Unit
(
11
)
Unscrew the drain sleeve (
11.1
) from the tun-
dish (
11.4
) and from above push with the seal
(
11.2
) through the drain opening in the wash-
basin and screw to the tundish applied below
the washbasin with the shaped seal (
11.3
).
Insert the two-piece pull rod in the fitting
body, screw in place and connect to the drain
unit using the hinge piece.
Technical Data
Flow rate
0.3 MPa =
^ 3.5 l/min
Test pressure
1.6 MPa max.
Operating
temperature
90 °C max.
2.4 Installation of MAZ
Insert the fitting with sealing ring (
9
) in the
washbasin and from below attach with U-
shaped washer (
11
), U-shaped thrust washer
(
12
) and clamping sleeve (
13
).
2.4.1 Water Connection
Connect the short connection hose marked
„blue“ (
6
,
×
blue ) to the angle valve -
cold
water supply pipe
.
Connect the two connection hoses to the
instantaneous water heater using union nuts
and seals.
Screw the connection hose (
7
,
Ø
blue) with
the downward-pointing arrow to the inlet
connector of the instantaneous water heater,
and connection hose (
8
,
×
red) with the up-
ward-pointing arrow to the outlet connector.
When fitting the connection hoses, note the
following
A
(see page 3):
– Do not bend hoses immediately after the
joint; leave a straight section of at least
15 mm;
– Do not kink hoses but ensure a minimum
curvature radius of 20 mm;
– Avoid distortion during fitting;
– Avoid tension during fitting;
– Twisting during fitting is not permitted.
Technical Data
Flow rate
0.3 MPa =
^ 3.5 l/min
Test pressure
1.6 MPa max.
Operating
temperature
90 °C max.
2.5 Installation of MAW
Screw the fitting with cover plate (
6
) into the
wall plate.
Screw the swivel outlet (
5
) to the fitting body
by turning the union nut.
Technical Data
Flow rate
0.3 MPa =
^ 3.5 l/min
Test pressure
1.6 MPa max.
Operating
temperature
90 °C max.
3. Environment and recycling
For guarantees please refer to the respecti-
ve terms and conditions of supply for your
country.
Please help us to protect the environment by
disposing of the packaging in accordance with
the national regulations for waste processing.
The installation, electrical connection
-
ler.
The company does not accept liability
for failure of any goods supplied which
are not installed in accordance with the
manufacturer‘s instructions.
4. Guarantree