STIEBEL ELTRON FES KOMFORT Скачать руководство пользователя страница 5

EN

G

LI

SH

OPERATION | INSTALLATION 

GENERAL INFORmATION

FES Comfort | TCR Comfort  

| 5

1.  General information

  

Read these instructions carefully and retain them 

for future reference. If the appliance is passed on to 

a third party please hand these instructions to the 

new user.

This document applies to:

 

— FES Komfort (Part no. 227664) 

 

— TCR Comfort (Part no. 190176)

1.1  Symbols in these instructions

In this documentation you will come across symbols and 
highlights. These have the following meaning:

 

Please read!  
Read the text next to these symbols carefully.

 

»

The "

»

" symbol indicates that you have to do something. The 

action you need to take is described step-by-step.

 

— Passages with this symbol "

" indicate lists.

2.  Operation

This control unit has the same functions as the control unit 
built into the ventilation unit. See the operating instructions for 
information on operation.  

3.  Installation

Installation, commissioning, maintenance and repair 
may only be carried out by a qualified heating contractor. 
Correct function can only be guaranteed if you observe the 
following:

 

— Fit the control unit onto an internal wall, but not in a recess.

 

— The control unit must not be covered up by a curtain or 

similar.

 

— Try to restrict the influence of heat from elsewhere (for 

example from the sun, central heating or TV set).

 

— Avoid direct draughts coming from windows and doors.
To install you must remove the control unit from the wall mounting 
enclosure:

 

26

_0

4_

01

_0

40

1

 

»

Reset the snap-in tabs found in the opening on the underside 
of the wall mounting enclosure. Press upon the snap-in tabs 
with a screwdriver.

 

»

Lay out a 4-core CAN-BUS cabe from the ventilation unit to the 
mounting position of the control unit. Use a screened electronic 
cable with a cable resistance of up to 70 Ohm/km and a wave 
resistance of 120 Ohm (for example HELUKABEL 4x1x0.34 mm², 
HELUKABEL-Artikel-Nr. 801573 - CAN BUS).

For installations of 20 to 30 cm the CAN-BUS cable must protrude 
from the wall. For securing to a wall we recommend a flush 
box, which can hold this part of the cable. Make sure that the 
screws supporting the flush box are arranged either vertically 
or horizontally opposite one another. The chapter "installation 
options" describes installation without a flush box.

26

_0

4_

01

_0

42

9

1

1  Flush box

 

»

Secure the wall mounting enclosure to the flush box using the 
screws provided.

26

_0

4_

01

_0

39

9

2

1

3

1  Programming unit
2  Wall mounting enclosure
3  6-pole CAN-BUS socket plug

286696-38753-9046_FES_Komfort_TCR_Comfort_de_en.indb   5

18.05.2015   10:11:17

Содержание FES KOMFORT

Страница 1: ...NSTALLATION OPERATION AND INSTALLATION BEDIENEINHEIT MIT WANDAUFBAUGEH USE CONTROL UNIT WITH WALL MOUNTED ENCLOSURE FES KOMFORT TCR KOMFORT 286696 38753 9046_FES_Komfort_TCR_Comfort_de_en indb 1 18 05...

Страница 2: ...nicht durch Vorh nge und dergleichen abgedeckt werden Verhindern Sie Beeinflussungen durch Fremdw rme zum Beispiel durch Sonne Heizung oder Fernsehger t Vermeiden Sie direkte Zugluft die durch Fenster...

Страница 3: ...itung eine Verbindung zwischen Ger t und Bedieneinheit her Verwenden Sie als Steckverbindung zur Bedieneinheit die bei gef gte 6 polige Anschlussklemmleiste Achten Sie auf die Polarit t am Ger t und a...

Страница 4: ...nden lang den Reset Schalter des L ftungs ger tes Alternativ k nnen Sie mittels Sicherung f nf Sekunden lang die Netzspannung des L ftungsger tes unterbrechen Hinweise zur Bedienung und Einstellung fi...

Страница 5: ...ered up by a curtain or similar Try to restrict the influence of heat from elsewhere for example from the sun central heating or TV set Avoid direct draughts coming from windows and doors To install y...

Страница 6: ...with the already routed data cable Use the 6 pole terminal strip provided as a plug in connection to the control unit Be sure to get the polarity right on the ventilation unit and the control unit Ven...

Страница 7: ...ve seconds Alternatively you can interrupt the power supply to the ventilation unit for five seconds via the fuse MCB See the operating and installation instructions for the ventilation unit for infor...

Страница 8: ...s techniques Onder voorbehoud van vergissingen en technische wijzigingen Salvo error o modificaci n t cnica R tt till misstag och tekniska ndringar f rbeh lls Excepto erro ou altera o t cnica Zastrze...

Отзывы: