background image

STIEBEL ELTRON

7

Operation Instruction 

for the user and the qualified installer

3.  Technical Data

Type 

DHC 8

 EL

Norminal capacity                                      l. 

0.45 

Design 

Close outlet

Max. water pressure 

1000 kPa

Min. water pressure to activate unit 

200 kPa

Water connection 

G ½“ (External Thread) (15mm)

Dimension (W x H x D)                       mm. 

360 x 200 x 110

Weight                                                        kg. 

2.0

Electrical connection 

1/N/PE/AC 220..240 V.

Rated power (kW)    Rated current  (A.) 

kW - A 

  

 220 V 

8.0 - 36.4 

  

 230 V 

8.7 - 37.8

  

 240 V 

9.5 - 39.6

Safety device 

 - 

4. Regulations and Provisions

  -  Regulations of the local power  

 

  supply company should be  

 

  observed.
  -  Regulations of the water supply  

 

  company should be observed
  -  Read & study the technical data.
  -  Install the unit vertically on the  

 

  wall.
  -  Electrical connection to be  

 

  secured.

    The device must be capable of 
    being isolated from the mains,  
 for example by fuses, with an isolating 
  distance of at least 3.5 mm. in all poles.

5.  Important notes

 

-  Make sure the data on the unit rating 

  

plate is current

 

-  Install the unit so that it is flush with 

  

the wall

 

-  Material for the water installation:

  

Steel, copper, or plastic piping 

  

systems.  If plastic piping systems are  

  

being used, the  following instructions 

  

are to be respected.

 

-  Temperature :    max 60 ˚C

 

-  Pressure :  1000 kPa

  

           The unit must be connected to 

    the protective earth conductor 
 

(see electric circuit diagram).

Installation must comply with 

AS/NZS 3500.4

Содержание DHC 8 EL

Страница 1: ...installed water and electrical installation commissioned and serviced by approved service technicians in accordance with these instructions English Instantaneous water heater Operation and installati...

Страница 2: ...STIEBEL ELTRON 2...

Страница 3: ...uctionstothenew user This appliance is not intended for use by persons including children with reduced physical sensory or men tal capabilities or lack of experi ence and knowledge unless they have be...

Страница 4: ...ch controls the operation of the heater electronically 1 2 Using the unit 1 Adjust the temperature using at the selector Level heats the water to a temperature of 40 C Level heats the water to a mediu...

Страница 5: ...tion downwards Warning For electrical heating appliances equipped with a heat cutoff device that does not reset automatically if you would like to reset the unit the mains power supply must be disconn...

Страница 6: ...ose the valve again WARNING When selecting an appropriate water temperature the temperature may be dangerously high especially for children Keep away from the hot water outlet as it may cause a potent...

Страница 7: ...tions of the water supply company should be observed Read study the technical data Install the unit vertically on the wall Electrical connection to be secured The device must be capable of being isola...

Страница 8: ...on and installation must be followed carefully They provide important information regarding safety operation and maintenance of the unit A damp cloth is sufficient to clean the unit Do not use any foa...

Страница 9: ...ser Fault Cause Rectification No hot water despite water flow through the unit The water flow volume required for the unit to turn it on has not been reached Increase flow volume Water flow too high R...

Страница 10: ...ng hole 2 Lower mounting hole 3 Depth for mounting screw Fig 7 3 4 Distance of the connection cable Fig 6 4 5 Thermostat 6 Cable entry with seal 7 Electrical connection 8 Plug connecting the circuit b...

Страница 11: ...lation to a shower sink Fig 5 Fig 6 Dimension Cable 4 100 mm 200 mm 35 mm G1 2 G1 2 110 mm 59 mm 280 mm 360 mm 270 mm 264 mm 9 mm 50 mm 65 mm STIEBEL ELTRON 11 Installation Instruction for the qualifi...

Страница 12: ...ting Element B Electronic control set C Control Triac set D Thermal cut out E Temperature Sensor Inlet F Temperature Sensor Outlet G ELCB option Fig 9 min 4 5mm max 5 5mm m m 6 4 x 35 mm 6 mm 4 x 35 m...

Страница 13: ...a hole in the wall Fig 7 Insert a wall plug and screw in the depth of the protruding screw head must be correct Fig 7 3 Remove the screw from underneath the water heater to open the cover of the unit...

Страница 14: ...that the power is turned off at the mains A circuit breaker or power control switch should be installed before the unit The size of the circuit breaker must corre spond to the voltage of the heater c...

Страница 15: ...e unit Fig 18 A to the joints both hot and cold water using a rubber leakage gasket Fig 18 C between the joints InstallingWater Heater wall mounted Connectingthewaterheatertoawall mounted water pipe C...

Страница 16: ...EL ELTRON 16 Installation Instruction for the qualified installer Install the cover Connect the power cordbetweenthecircuitboardandthecover After installation is complete close the casing and screw in...

Страница 17: ...STIEBEL ELTRON 17...

Страница 18: ...STIEBEL ELTRON 18...

Страница 19: ...STIEBEL ELTRON 19...

Страница 20: ...Part no 7901 293468 Part name OPERATING INSTRUCTION DHC 8 EL En Product code DHC 8 EL 233948...

Отзывы: