6

 | CE CES CERO SERIES 

WWW.STIEBEL-ELTRON-USA.COM

INSTALLATION  

 

MOUNTING THE WATER HEATER

INSTALLATION

5.  Mounting the water heater

!

 

CAUTION

: Injury

Hot water outlet pipes leaving unit can be hot to the 
touch. Insulation must be used for hot water pipes below 
36˝ (0.9 m) due to burn risk to children.

!

 

NOTICE:

This unit should not be installed in a location
where it may be exposed to temperatures less than
36 °F (2 °C). If the unit may be subject to freezing tempera-
tures all water must be drained from the unit.
Failure to comply with this instruction voids all warranties.
The unit should be located in an area where water
leakage from the unit or connections will not result in
damage to the area adjacent to the unit. If such a location 
cannot be avoided it is recommended that a drain
pan be installed under the unit.

Application

Before mounting, double check that the correct voltage the unit 
requires matches the voltage of the local power supply. The voltage 
and configuration (Wye or Delta) are declared on the nameplate. 
Make sure that the supply wire size corresponds to the heater ca-
pacity and wire run according to NEC. Installation carried out by a 
licensed electrician will ensure this. The hot water supply includes an 
air vent. The incoming water supply is equipped with a pre-installed 
pressure relief valve. For water supply line positions, see section 
10.4, “Dimension drawings”, pg. 11.

5.1 Mounting

 

f

Install the water heater as close as possible to the main hot 
water draw off points.

 

f

Keep a minimum of 5˝ (127 mm) clearance on all sides for 
service.

 

f

NEMA 3 enclosures require a minimum clearance of 20˝ (510 
mm) on the front side to allow the hinged cover to be fully 
opened.

 

f

If there is a drain tube connected to the pressure relief valve, 
make sure that the drain water is not blocked by anything.

5.1.1  Enclosure dimensions, excluding plumbing fittings

NEMA 3

NEMA 4 / 4X

 

Capacity

No. of  

Elements

Width 

(X)

Height 

(Y)

Depth 

(Z)

Width 

(X)

Height 

(Y)

Depth 

(Z)

12–18

 kW

3

16 

1

/

16

˝

15 

1

/

8

˝

1

/

8

˝

24˝

24˝

9 ½˝

24–36

 kW

6

18 

5

/

8

˝

21 

7

/

8

˝

9 ¼˝

24˝

24˝

9 ½˝

48–72

 kW

12

18 

5

/

8

˝

30 ½˝

9 ¼˝

24˝

48˝

13 

5

/

8

˝

81–108

 kW

18

24˝

48˝

13 

5

/

8

˝

24˝

48˝

13 

5

/

8

˝

120–144

 kW

24

24˝

48˝

13 

5

/

8

˝

24˝

48˝

13 

5

/

8

˝

5.1.2  Mounting screw positions

Enclosure

3-element 

12–18 kW

6-element 

24–36 kW

12-element 

48–72 kW

NEMA 3 - (A) X/Y

1

/

8

˝ / 17 

1

/

8

˝

5

/

16

˝ / 23 

7

/

8

˝

5

/

16

˝ / 32 

3

/

8

˝

NEMA 4 - (B) X/Y

22 

7

/

16

˝ / 25 ¼˝

22 

7

/

16

˝ / 25 ¼˝

22 

7

/

16

˝ / 49 ¼˝

NEMA 4X - (B) X/Y 22 

7

/

16

˝ / 25 ¼˝

22 

7

/

16

˝ / 25 ¼˝

22 

7

/

16

˝ / 49 ¼˝

Enclosure

18-element 

81–108 kW

24-element 

120–144 kW

NEMA 3 - (B) X/Y

22 

7

/

16

˝ / 49 ¼˝

22 

7

/

16

˝ / 49 ¼˝

NEMA 4 - (B) X/Y

22 

7

/

16

˝ / 49 ¼˝

22 

7

/

16

˝ / 49 ¼˝

NEMA 4X - (B) X/Y 22 

7

/

16

˝ / 49 ¼˝

22 

7

/

16

˝ / 49 ¼˝

6. Water 

connections

!

 

NOTICE:

Excessive heat from soldering on copper pipes near the  
heater may cause damage.

!

 

NOTICE:

Hard water or water with a high mineral count may dam-
age the unit. Damage to the unit caused by scale or a high 
mineral count is not covered under the warranty.

6.1 

Venting the air

 

f

Before the heater is connected to the water supply, make sure 
that the water supply is flushed first to ensure it is free from 
any scale and dirt. The water pressure needs to be less than 
145 psi (10 bar).

 

f

If the water pressure exceeds 145 psi (10 bar), install a pressure 
reducing valve in the cold water pipework. Cold water supply 
(inlet) is located on the bottom right.

 

f

Before the heater is connected to the electric supply, make sure 
that the water supply line is flushed for 3 minutes minimum to 
vent any air pockets out of the tubing system.

 

f

Open the service screw on the vent valve to release the air.

 

f

Open and close the ball valve on the cold water supply side 
several times to release any air pockets from the heater.

 

f

Once the air is released, close the screw on the vent valve.

A

B

Содержание CE 108 KW

Страница 1: ...499 Certi ed to CAN CSA Std C22 2 No 88 CE CES CERO 12 KW CE CES CERO 15 KW CE CES CERO 18 KW CE CES CERO 24 KW CE CES CERO 27 KW CE CES CERO 36 KW CE CES CERO 48 KW CE CES CERO 54 KW CE CES 60 KW CE...

Страница 2: ...________ 3 2 1 Intended use_________________________________________________________ 3 2 2 Safety precautions__________________________________________________ 3 2 3 Test symbols _____________________...

Страница 3: ...censed electrician and plumber The installation must comply with all national state and local plumbing and electric codes Service of the water heater must be performed by quali ed service technicians...

Страница 4: ...d 120 144 kW models contain 24 heating elements The elements used in different con gurations are for 208 240 277 and 288 V CE CES CERO models are available in a NEMA 3 standard a NEMA 4 optional or a...

Страница 5: ...in breaker back on Turn on the heater on off switch 12 For resistivity test turn the breaker off and check voltage just in case 4 1 Fault table Symptom Possible cause Action No hot water A B C D E F G...

Страница 6: ...be connected to the pressure relief valve make sure that the drain water is not blocked by anything 5 1 1 Enclosure dimensions excluding plumbing ttings NEMA 3 NEMA 4 4X Capacity No of Elements Width...

Страница 7: ...ing to NEC Wire gauge AWG Torque lb in 8 80 6 4 165 3 275 The water heater should be connected to a properly grounded ded icated branch circuit of proper voltage rating In installations with several C...

Страница 8: ...00 32 48 40 CE 36 KW CE 036 208D 208 36 00 99 93 110 6 185 8 x 217 8 x 9 CE 036 240D 240 36 00 86 60 100 CE 036 400D 400 33 28 48 04 60 CE 036 400Y 400 Wye 33 06 47 72 60 CE 036 480D 480 36 00 43 30 5...

Страница 9: ...CES 36 KW CES 036 208D 208 36 00 99 93 110 6 185 8 x 217 8 x 9 CES 036 240D 240 36 00 86 60 100 CES 036 400D 400 33 28 48 04 60 CES 036 400Y 400 Wye 33 06 47 72 60 CES 036 480D 480 36 00 43 30 50 CES...

Страница 10: ...00 24 09 30 CERO 27 KW CERO 027 208D 208 27 04 75 06 80 6 185 8 x 217 8 x 9 CERO 027 240D 240 27 02 65 01 80 CERO 027 480D 480 27 02 32 50 40 CERO 36 KW CERO 036 240D 240 36 00 86 60 100 6 185 8 x 21...

Страница 11: ...CERO 12 18 NEMA 3 enclosure C B D A E Capacity No of Elements A B C D E 12 18 kW 3 253 8 91 8 161 16 151 8 2 10 4 2 CE CES CERO 12 36 NEMA 4 4X enclosure C G B D A E F Capacity No of Elements A B C D...

Страница 12: ...0 4 3 CE CES CERO 24 36 NEMA 3 enclosure C B D A E Capacity No of Elements A B C D E 24 36 kW 6 323 8 9 185 8 217 8 3 10 4 4 CE CES CERO 48 72 NEMA 3 enclosure C B D A E Capacity No of Elements A B C...

Страница 13: ...A 10 4 5 CE CES CERO 81 144 NEMA 3 enclosure CE CES CERO 48 144 NEMA 4 4X enclosure C G B D A E F Capacity No of Elements A B C D E F G 48 72 kW 12 503 8 135 8 24 48 4 375 8 321 8 81 108 kW 18 503 8 1...

Страница 14: ...r CE CES CERO 12 208 240 V CE CES CERO 15 208 240 V CE CES CERO 18 208 240 V A1 Thermistor D1 F1 F3 Fuse FS1 Flow sensor G1 D G2 K P1 Low pressure switch R1 R3 Resistance element S1 K S2 d T1 T3 Therm...

Страница 15: ...12 400 480 V Wye CE CES CERO 15 400 480 V Wye CE CES CERO 18 400 480 V Wye A1 Thermistor D1 F1 F3 Fuse FS1 Flow sensor G1 D G2 K P1 Low pressure switch R1 R3 Resistance element S1 K S2 d T1 T3 Thermos...

Страница 16: ...ERO 24 208 240 V CE CES CERO 27 208 240 V CE CES CERO 36 208 240 V A1 Thermistor D1 F1 F6 Fuse FS1 Flow sensor G1 D G2 K P1 Low pressure switch R1 R6 Resistance element S1 K S2 d T1 T6 Thermostat TR1...

Страница 17: ...27 400 480 V CERO 27 480 V CE CES CERO 36 400 480 V A1 Thermistor D1 F1 F3 Fuse FS1 Flow sensor G1 D G2 K P1 Low pressure switch R1 R6 Resistance element S1 K S2 d T1 T6 Thermostat TR1 TR3 Triac TX1 d...

Страница 18: ...24 575 V CE CES CERO 36 575 V A1 Thermistor D1 F1 F3 Fuse FS1 Flow sensor G1 D G2 K P1 Low pressure switch R1 R6 Resistance element S1 K S2 d T1 T6 Thermostat TR1 TR3 Triac TX1 d X0 Main terminal bloc...

Страница 19: ...CE CES 54 208 240 V CERO 54 240 V CE CES 60 208 240 V CE CES 72 208 240 V CERO 72 240 V t W Delta Configuration L1 E3 E1 E2 L2 L3 HX Flow Layout A1 Thermistor D1 F1 F12 Fuse FS1 Flow sensor G1 D G2 K...

Страница 20: ...4 480 V CE CES 60 400 480V CE CES 72 480 V CERO 72 400 480 V t W A1 Thermistor D1 F1 F6 Fuse FS1 Flow sensor G1 D G2 K P1 Low pressure switch R1 R12 Resistance element S1 K S2 d T1 T12 Thermostat TR1...

Страница 21: ...RO 48 575 V CE CES CERO 72 575 V t W A1 Thermistor D1 F1 F6 Fuse FS1 Flow sensor G1 D G2 K P1 Low pressure switch R1 R12 Resistance element S1 K S2 d T1 T12 Thermostat TR1 TR6 Triac TX1 d X0 Main term...

Страница 22: ...O 144 400 480 V A1 A2 Thermistor 1 Thermistor 2 D1 F1 F12 Fuse FS1 Flow sensor 1 FS2 Flow sensor 2 G1 D G2 K P1 Low pressure switch R1 R24 Resistance element S1 K S2 d T1 T24 Thermostat TR1 TR12 Triac...

Страница 23: ...A COM CE CES CERO SERIES 23 ENGLISH INSTALLATION TECHNICAL DATA 10 5 10 CE CES CERO 120 CE CES CERO 144 400 V 480 V Delta wiring diagram page 2 This diagram is valid for CE CES CERO 120 400 480 V CE C...

Страница 24: ...mistor 1 Thermistor 2 D1 F1 F12 Fuse FS1 Flow sensor 1 FS2 Flow sensor 2 G1 D G2 K P1 Low pressure switch R1 R24 Resistance element S1 K S2 d T1 T24 Thermostat TR1 TR12 Triac TX1 d X0 Main terminal bl...

Страница 25: ...WWW STIEBEL ELTRON USA COM CE CES CERO SERIES 25 ENGLISH INSTALLATION TECHNICAL DATA 10 5 12 CE CES CERO 144 575 V Delta wiring diagram page 2 This diagram is valid for CE CES CERO 144 575 V...

Страница 26: ...1 8 GPH 737 492 369 295 246 211 184 164 147 134 123 113 105 48 kW GPM 16 4 10 9 8 2 6 6 5 5 4 7 4 1 3 6 3 3 3 0 2 7 2 5 2 3 GPH 983 655 492 393 328 281 246 218 197 179 164 151 140 54 kW GPM 18 4 12 3...

Страница 27: ...ugh the heater If the cut off has no continuity it should be replaced Make sure that the water is drained and the power supply is off Remove the wires to the cut off with a athead screwdriver Remove t...

Страница 28: ...nuity the pressure switch is not the cause f If there is no continuity drain the water from the heater and remove the wires from the switch Mark the wires with the switch pole designation Pole nb 1 ne...

Страница 29: ...orized to make all warranties on Manufacturer s behalf and no statement warranty or guarantee made by any other party shall be binding on Manufacturer Manufacturer shall not be liable for any damage w...

Страница 30: ...30 CE CES CERO SERIES WWW STIEBEL ELTRON USA COM NOTES...

Страница 31: ...WWW STIEBEL ELTRON USA COM CE CES CERO SERIES 31 NOTES...

Страница 32: ...5537 Fax 941 755 6529 tanklessinc stiebel eltron usa com 17 West Street West Hat eld MA 01088 Tel 413 247 3380 Fax 413 247 3369 info stiebel eltron usa com www stiebel eltron usa com Rev 1 2020 Subjec...

Отзывы: