STIEBEL ELTRON AQ 35 E-2 Скачать руководство пользователя страница 19

 
 

19 

 

 

    7.3 Spare Parts list, Model: AQ 60E 

 

(Effective since October 2005) 

Item 

Part no. 

Part name 

Quantity 

Remark 

6701-269827 

Filter Thai 

 

 

 

4401-269842 

Reed Switch Housing  Wire, Black 

 

 

 

7701-269562 

O-Ring 8 * 1.5 

 

 

6301-269819 

Plastic Flow Body 16 mm., Black 

 

 

4301-269709 

Magnet Set (P+M+P) 

 

7701-269564 

Silicone Gasket 12 * 20 * 4 

 

6201-275936 

Triac PCB BTA 41 # 12 Ring With Transil Diode 

 

6801-269832 

Cooling Plate 

 

 

7701-269563 

O-Ring 21.3 * 1.8 

 

 

10 

4301-281686 

Black Plastic Inlet Set, For Copper Tank 

 

 

11 

7701-269559 

Silicone Gasket 12 * 18.5 * 2.5 

 

 

20 

6102-267319 

Copper Tank VBC, Dia 54*127, 1E (6.0 Kw) 

 

 

21 

7501-269439 

Tank Sticker 3.4 X 1.7 Cm 1.5" 

 

 

22 

6801-267320 

Bracket For Copper Tank Dai. 54 mm 

 

25 

6202-275484 

Double Action Thermostat For Copper Tank 45A 

 

 

26 

6801-275556 

Bracket For Thermostat 25A/45A For Copper Tank 

 

30 

6201-267393 

Control PCB PC-CB With ELSD 

 

 

31 

6201-267389 

Button PCB DS 

 

 

35 

6301-165511 

Plastic Nipple/Adapter  

 

Effected since 

November 2009 

6302-165511 

Plastic Nipple/Adpter G 1/2" 

1  

Replaced by             

6301-165511 

36 

7701-165828 

O-Ring 9 * 2.5 

 

 

37 

7801-269566 

Clip Lock 

 

 

45 

6301-271295 

Knob AEG / MST Set Thai 

 

AEG 

46 

6301-267373 

Knob Lock Thailand 

 

 

47 

6501-267324 

Front Sticker AQ 60 E 

 

AEG 

48 

6301-269707 

Plastic Cover - AEG 

 

AEG 

49 

6301-267346 

Base Thailand 

 

 

50 

6001-158869 

Cable Entry Rubber Seal 

 

 

55 

6302-281966 

Terminal Block TLB-500W-0392-3P-XS 

 

 

56 

6301-269818 

Plastic Insert Support PCB 

 

 

57 

7302-161911 

Spacer 

 

Replaced by             

7301-281813 

7301-281813 

PCB Spacer 

 

Effected since     

January 2009 

58 

6301-267372 

Plastic Knob Adapter Thailand 

 

 

 

Содержание AQ 35 E-2

Страница 1: ...1 Service Manual AQ 35 45 E 2 Author Mr Apiwat Limrueangwattanakul Revision version 1 0...

Страница 2: ...Checking 9 3 Flow Switch Checking 10 3 1 Set unit at vertical direction 10 3 2 Set unit to upside down turn 180 direction 11 3 3 The other way to activate Flow Switch 12 4 PCB Control Checking 13 5 Th...

Страница 3: ...3 Warning Warning This service manual is suitable for qualified Technicians only Warning Disconnect power supply before open cover...

Страница 4: ...lly controlled The flow is switched on and off by using a water valve The unit switches the power on once the flow volume is sufficient The Power light indicates that the unit is switched on Any desir...

Страница 5: ...r Water Connector G 1 2 Power Supply 1 N PE 220 240 V Rated Power 220 V kW A 3 5 15 29 4 5 20 5 Rated Power 230 V kW 3 8 16 5 4 9 21 3 Rated Power 240 V kW 4 2 17 5 5 4 22 5 Cable Size Sq mm 2 5 4 0 2...

Страница 6: ...ng Diagram Type AQ E 2 A Heating element B Electronic control set Phase Cut C ELSD Circuit Option D Single Triac Set E Thermal cut out TCO F Button Board Option G Current Leakage Sensor Option G E A D...

Страница 7: ...hot Water leak Tight connectors Connector has loosen Wrong installation Reinstallation Lamp broken Lamp cable broken Check change the Lamp Check change Lamp cable Power lamp not ON But water Hot Water...

Страница 8: ...Set Multi meter to Ohm range or and check as show in the pictures Check Meter Result Cause Action Pole Pole Beep signal or 0 Element Pass No action No signal OL or Element Broken Change New Heater Po...

Страница 9: ...tures Note L1 line H1 Heater GRD Ground Check Meter Result Cause Action L1 H1 Beep signal or 0 Triac short circuit Change new No signal OL or Triac Pass No action Check Meter Result Cause Action L1 GR...

Страница 10: ...t standby Flow Switch Reed SW still open circuit as no water supply Set Multi meter to Ohm range or and unplug the reed switch connector from the Control PCB and check Reed Switch as in the pictures C...

Страница 11: ...Switch Reed SW become close circuit Check Result Cause Action Pole Pole Beep signal or 0 Pass No action No signal OL or Reed SW contact closed Change new one Remark OL Over Load for Digital Multimeter...

Страница 12: ...w Switch Check Result Cause Action Pole Pole Beep signal Pass No action No signal OL or Reed SW not activate Check Magnet Remark OL Over Load for Digital Multimeter Over Load for Analog Multimeter Pol...

Страница 13: ...13 4 PCB Control Checking Check Result Cause Action Visual Electronic equipment burn PCB short circuit Change new one No visible damage PCB failure Change new one Visual check...

Страница 14: ...e down lower than 45 it become connect power system again In case temperature high up with any abnormal case until 7 it will fully cut out the power The technician must fix Root cause first before res...

Страница 15: ...but keep the main breaker to the unit turned off 3 Check leak point by visual If have some leak please change O Ring or gasket If Power Lamp on mean Triac Damage Must change new one 4 Continuous suppl...

Страница 16: ...16 7 AQ_E 2 Parts List...

Страница 17: ...ble Action Thermostat 16A For Copper Tank 1 26 6801 267307 Thermostat Bracket 1 30 6201 267393 Control PCB PC CB With ELSD 1 31 6201 267389 Button PCB DS 1 35 6301 165511 Plastic Nipple Adapter 1 Effe...

Страница 18: ...mostat For Copper Tank 45A 1 26 6801 275556 Bracket For Thermostat 25A 45A For Copper Tank 1 30 6201 267393 Control PCB PC CB With ELSD 1 31 6201 267389 Button PCB DS 1 35 6301 165511 Plastic Nipple A...

Страница 19: ...Tank Dai 54 mm 1 25 6202 275484 Double Action Thermostat For Copper Tank 45A 1 26 6801 275556 Bracket For Thermostat 25A 45A For Copper Tank 1 30 6201 267393 Control PCB PC CB With ELSD 1 31 6201 2673...

Отзывы: