| ACCELERA® 300 HEAT PUMP WATER HEATER
WWW.STIEBEL-ELTRON-USA.COM
INSTALLATION
WATER HEATER DESCRIPTION
9. Water heater description
3
2
1
4
5
26
�0
3�
02
�1
40
4
1 High limit safety cut-out - manual reset
2 Compressor
3 Condensate drain
4 Filter dryer
5 Service valve, high pressure
6 Sacrificial anode
8
7
9
10
26
�0
3�
02
�1
40
5
7 Capacitor
8 Fan
9 Evaporator
10 Defrost sensor
The hot water thermostat temperature is preset at the
factory.
Where customers require a lower hot water
temperature, the thermostat settings of the heat pump
and the booster heater can be reduced.
A sacrificial anode rod is installed in the top of the water heater. (6)
9.1 Standard delivery
- Accelera 300 heat pump water heater
- Two adaptors, Union to
¾
"
- Two union gaskets
- Condensate drain elbow
- Two copper crush caps
- 100 psi T&P valve
9.2 Special accessories
Description
Part number
Anode rod
278235
Segmented anode rod
143498