iNSTallaTiON
installation
EN
GL
ISH
www.stiebel-eltron.com
PEO 18/21/24 | PEO 27 |
7
Oversink installation
1
2
26
�02
�02
�1
34
4
1 Cold water inlet
2 DHW outlet
Note
f
f
Mount the appliance on the wall. The wall must have
sufficient load bearing capacity.
9.2 Water installation
- No safety valve is required.
- Safety valves are not permissible in the DHW pipe.
f
f
Flush the water line thoroughly.
f
f
Ensure that the flow rate for switching on the appliance is
achieved (see chapter "Specification / Data table", On). If the
flow rate is not achieved, remove the flow limiter (see chap-
ter "Installation / Removing the flow limiter").
f
f
Increase the mains water pressure if the required flow rate is
not achieved with the draw-off valve fully opened.
Taps
Use appropriate pressure taps. Open vented taps are not per-
missible.
Note
Never use the shut-off valve in the cold water inlet to
reduce the flow rate. It is intended for shutting off the
appliance.
Permissible water line materials
- Cold water inlet pipe:
Pipes made from galvanised steel, stainless steel, copper or
plastic
- DHW outlet line:
Pipes made from stainless steel, copper or plastic
!
Material losses
If plastic pipework systems are used, take into account
the maximum inlet temperature and the maximum pres-
sure (see chapter "Specification / Data table").
Flexible water connection lines
f
f
If the appliance is installed with flexible water connection
lines, ensure that the pipe bends with bayonet fittings do not
become twisted inside the appliance.
f
f
Secure the back panel at the bottom with two additional
screws.
10. Installation
10.1 Standard installation
- Electrical connection from above; installation on unfinished
walls
- Water connection on unfinished walls
- PEO 18/21/24: Medium connected load is selected
For further installation options, see chapter "Alternative instal-
lation methods":
- Electrical connection from below on unfinished walls
- Electrical connection on finished walls
- Connecting a load shedding relay
- Water installation on finished walls
- Water connection on unfinished walls for appliance
replacement
- Operation with preheated water
- Temperature limit
Opening the appliance
D
00000
41
61
5
f
f
Open the appliance by releasing the snap lock.
NT
T-
so
X1
26
�02
�02
�0
762
f
f
Remove the back panel by pressing the two locking tabs and
pulling the lower section of the back panel forwards.
Содержание 233991
Страница 65: ...www stiebel eltron com PEO 18 21 24 PEO 27 65 1 1 1 1 1 1 f f 1 1 2 1 1 3...
Страница 66: ...66 PEO 18 21 24 PEO 27 www stiebel eltron com 1 2 f f f f 1 3 2 2 1 2 2 60 C 43 C 3 3...
Страница 79: ...www stiebel eltron com PEO 18 21 24 PEO 27 79...
Страница 81: ...www stiebel eltron com PEO 18 21 24 PEO 27 81 1 1 1 1 1 1 f f 1 1 2 1 1 3...
Страница 82: ...82 PEO 18 21 24 PEO 27 www stiebel eltron com 1 2 f f f f 1 3 2 2 1 2 2 60 C 43 C 3 3...
Страница 84: ...84 PEO 18 21 24 PEO 27 www stiebel eltron com 7 7 1 60 7 2 f f Tred f f ZTA 3 4 7 3 IP 25 8 8 1 2 2...
Страница 92: ...92 PEO 18 21 24 PEO 27 www stiebel eltron com 13 1 3 2 5 DFE DFE 3 45 C 45 C 14 f f f f f f f f 26_02_02_0949...