EN
GL
ISH
WWW.stiebel-eltron.COM
SBS 601-1501 W SOL |
21
Installation
Specification
Recommended connection allocation SBS 801 W | SBS 801 W SOL
h23
h40
d46
h05
h22
h42
h06
h41
h28
h02
i07
d47
c01
d11
d17
e02
d26
e01
d12
d18
c06
d25
d07
d08
22,5°
22,5°
877
697
597
477
377
277
1600
D
00000
17
39
5
SBS 801 W SBS 801 W
SOL
c01 Cold water inlet
Male thread
G 1 1/4 A
G 1 1/4 A
c06 DHW outlet
Male thread
G 1 1/4 A
G 1 1/4 A
d07 Heat pump heating
flow
Male thread
G 1 1/2 A
G 1 1/2 A
d08 Heat pump heating
return
Male thread
G 1 1/2 A
G 1 1/2 A
d11 Heat pump DHW flow Male thread
G 1 1/2 A
G 1 1/2 A
d12 Heat pump DHW
return
Male thread
G 1 1/2 A
G 1 1/2 A
d17 Flow 2nd heat source Male thread
G 1 1/2 A
G 1 1/2 A
d18 Return 2nd heat
source
Male thread
G 1 1/2 A
G 1 1/2 A
d25 Solar flow
Female thread
G 1
d26 Solar return
Female thread
G 1
d46 Ventilation
Female thread
G 1/2
G 1/2
d47 Drain
Male thread
G 3/4 A
G 3/4 A
e01 Heating flow
Male thread
G 1 1/2 A
G 1 1/2 A
e02 Heating return
Male thread
G 1 1/2 A
G 1 1/2 A
SBS 801 W SBS 801 W
SOL
h02 Sensor heat pump
return
Diameter
mm
9.5
9.5
h05 Sensor heat pump
DHW
Diameter
mm
9.5
9.5
h06 Sensor heat pump
DHW opt.
Diameter
mm
9.5
9.5
h22 Sensor heat source
Diameter
mm
9.5
9.5
h23 Sensor heat source
opt.
Diameter
mm
9.5
9.5
h28 Sensor solar cylinder Diameter
mm
9.5
h40 Thermometer DHW
Diameter
mm
14.5
14.5
h41 Thermometer solar
Diameter
mm
14.5
h42 Thermometer heating Diameter
mm
14.5
14.5
i07 Electric emergency/
booster heater
Female thread
G 1 1/2
G 1 1/2
If the system configuration is different, the connection allocation can be changed.