Stid SLA-R41-A-U04 Скачать руководство пользователя страница 2

 
SPECTRE Access UHF 
Read only 
Installation procedure 

 

 
UHF SPECTRE Access 
Lecture seule   
Notice d’installation

 

 
UHF SPECTRE Access 
Solo lectura 
Manual de instalación

 

 

 

© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1127X03 - Page 

1

 sur 

15 

-

 

Ed. 16/05/2019 

 

SPECTRE Module Access - SMA

 

SPECTRE Reader Access - SLA

 

Frequency Band: 865 - 868 MHz

 

SMA-R41-A-U04: TTL 
SMA-R42-A-U04: RS232

 

SMA-R43-A-U04: RS485

 

Frequency Band: 865 - 868 MHz

 

SLA-R41-A-U04: TTL 
SLA-R42-A-U04: RS232 
SLA-R43-A-U04: RS485

 

Frequency Band: 902 - 928 MHz

 

SMA-R51-A-U04: TTL 
SMA-R52-A-U04: RS232 
SMA-R53-A-U04: RS485

 

Frequency Band: 902 - 928 MHz

 

SLA-R51-A-U04: TTL 
SLA-R52-A-U04: RS232 
SLA-R53-A-U04: RS485

 

 

Power Supply Characteristics - SMA /SLA 

Use an AC/DC power supply LPS type, Limited Power Source (as per IEC EN 60950-1 Ed2) or ES1 type, PS1 (as per IEC EN 62368-1) for main supply and for 
an eventual V+/V-. 
Main power supply:  Range +9 Vdc up to +36 Vdc   

Typical: 12 Vdc 

Consumption: 

Typical: 1A under +12 Vdc 

 

Max: 1.5A under +12 Vdc 

 

Characteristics - SMA / SLA 

Communication:  

RS485 (L+ & L-) / RS232 (TD & RD) / TTL (Wiegand / Clock & Data) 

Pin out:  

 

Removable connectors 3x4 pins and 1x8 pins, thread 3.81 mm / 0.149 in 

Temperature: 

-25 to +60 °C / -13 to +140 °F  

Protection:   

IP66 level 

Chip: 

 

EPC1 Gen2 (ISO 18000-63) - 1 to 62 bytes max 

I/O: 

 

4 optocoupled inputs and 4 optocoupled outputs 

Module LED: 

1 red LED: presence of power supply and 1 green LED: activity on Reader / host link 

Antenna LED: 

7 configurable colors (red, green, blue, orange, purple, turquoise, white) 

 

Recommended Cables - SMA / SLA 

Use a multi-conductor shielded twisted pair cable.  
Max length RS485:    3 280.84 ft / 1000 m at 9600 baud.  

 

Max length RS232:    49.21 ft / 15 m. 

 

Wiegand / Clock & Data: 

1 pair AWG24 

– 30 m / 98.43 ft max 

2 pairs AWG24 

– 60 m / 196.85 ft max 

3 pairs AWG24 

– 100 m / 328.08 ft max 

1 pair AWG20 

– 50 m / 164.04 ft max   2 pairs AWG20 – 100 m / 328.08 ft max   

Recommendations - SMA / SLA 

  Install the module/reader away from computer transmission cables or from power sources (ex: RJ45, sector

…).  

The disruptions that they can cause can vary according to their radiation power and their proximity. 

  Use a filtered and regulated power supply. 

  Antennas connected to different modules/readers may interfere with each other. Move them away from each other. 

  A power supply which provides 1.5 A min under +12Vdc is recommended. 

If the IN/OUT are powered by the module, use a 2A min under +12Vdc power supply. 

 

Users must not remain within a range of less than, 34 cm / 13.39 in

 

from an antenna for an extended period of time as per EN50364 applicable to this 

type of device.

 

  Apart from the hatch the module housings must not be opened. 

 

Before any service operation you must de-energize reader

  Check that the hatch seal is correctly positioned before closing. 

 

  Do not remove the caps of unused  

cable glands: 

  Do not remove the caps from the unused 

RF connectors: 

  Install the module/reader with the word 

UP  

facing upwards

 so that the connectors are down: 

 
 
 

      

 

 

 

Host Connection Access - SMA / SLA 

In order to access the module/reader connectors, open 

only

 

the hatch provided for this purpose by unscrewing the 4 captive screws without removing them from 

the hatch. 
 
 
 
 
 
 
 
 
 
 
 

 

Front View of the Module - SMA / SLA 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Red LED 

Green LED 

RF port 1 

Cable glands (Data Bus-Power sup. - Input/Output) 

RF port 2 

RF port 3 

RF port 4 

US 

FR 

ES 

Содержание SLA-R41-A-U04

Страница 1: ...Installation procedure Notice d installation Manual de instalación ...

Страница 2: ...lded twisted pair cable Max length RS485 3 280 84 ft 1000 m at 9600 baud Max length RS232 49 21 ft 15 m Wiegand Clock Data 1 pair AWG24 30 m 98 43 ft max 2 pairs AWG24 60 m 196 85 ft max 3 pairs AWG24 100 m 328 08 ft max 1 pair AWG20 50 m 164 04 ft max 2 pairs AWG20 100 m 328 08 ft max Recommendations SMA SLA Install the module reader away from computer transmission cables or from power sources ex...

Страница 3: ...nna LED flashes color RFON 200ms blue by default RFOFF 200ms If any tag is detected the antenna LED displays the sequence color RFON blue by default color DETECTION orange by default for 200ms then LED OFF If a configuration tag is detected the antenna LED displays the sequence color RFON blue by default color DETECTION orange by default for 200ms then LED OFF then the antenna LED gives the follow...

Страница 4: ...ble wall mounted kit refer to the Installation Procedures for KFX UHF 08 Adjustable pole mounted kit refer to the Installation Procedures for KFX UHF 09 Or mount directly on a wall Ø4x35 aluminum screws provided TCL ALU 4x12 Antenna Connection SMA An antenna must be connected to the RF port 1 closed to the LEDs RF Port 1 4 serializable cable lengths are available 1 5 m 4 92 ft CAB SPECTRE 1 5M 3 m...

Страница 5: ...79 in Standard VESA mounting bracket M4x12 polier screws provided with mounting kit Two mounting possibilities Adjustable wall mounted kit refer to the Installation Procedures for KFX UHF 08 Adjustable pole mounted kit refer to the Installation Procedures for KFX UHF 09 Antenna Connection SLA Antenna Cables SMA SLA The antenna cables have a male connector and a female connector Antenna must be con...

Страница 6: ... are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can emit radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipme...

Страница 7: ...ndé par tresse reliée à la masse du concentrateur Déport max RS485 1000 m à 9600 bauds Déport max RS232 15 m Wiegand Clock Data 1 paire 6 10 30 m max 2 paires 6 10 60 m max 3 paires 6 10 100 m max 1 paire 9 10 50 m max 2 paires 9 10 100 m max Recommendations SMA SLA Installer le module à distance des câbles de transmission informatique ou d origine de puissance ex RJ45 secteur Les perturbations qu...

Страница 8: ...uleur RFON 200 ms par défaut bleu RFOFF 200ms Si détection d un tag quelconque la LED antenne enchaîne la séquence couleur RFON par défaut bleu couleur DETECTION par défaut orange pendant 200ms puis LED OFF Si détection d un tag de configuration la LED antenne enchaîne la séquence couleur RFON par défaut bleu couleur DETECTION par défaut orange pendant 200ms puis LED OFF puis la LED antenne donne ...

Страница 9: ... murale orientable se référer à la Notice d installation du KFX UHF 08 Kit de fixation mât orientable se référer à la Notice d installation du KFX UHF 09 Ou Fixation directement sur un mur Vis Ø4x35 inoxydable recommandée Raccordement antennes SMA Il est impératif de raccorder une antenne sur le port RF 1 le plus proche des LEDs Port RF 1 4 longueurs de câbles sérialisables sont disponibles 1 5 m ...

Страница 10: ...ype VESA standard 75x75 mm vis M4x12 Inox fournies dans le kit de fixation Deux modes de fixation possibles Kit de fixation murale orientable se référer à la Notice d installation du KFX UHF 08 Kit de fixation mât orientable se référer à la Notice d installation du KFX UHF 09 Raccordement antenne s SLA Câbles antennes SMA SLA Les câbles antenne possèdent 1 connecteur mâle et un connecteur femelle ...

Страница 11: ...s limites sont conçues pour fournir une protection raisonnable contre les interférences nuisibles lorsque l équipement est utilisé dans un environnement résidentiel Cet équipement génère utilise et peut émettre des fréquences radio et s il n est pas installé et utilisé conformément aux instructions peut créer des interférences nuisibles perturbant les communications radio Toutefois rien ne permet ...

Страница 12: ... trenza conectado a la masa del concentrador Desvío máx RS485 3 280 84 ft 1000 a 9600 baudios Desvío máx RS232 49 21 ft 15 m Wiegand Clock Data 1 par 6 10 30 m 98 43 ft máx 2 pares 6 10 60 m 196 85 ft máx 3 pares 6 10 100 m 328 08 ft máx 1 par 9 10 50 m 164 04 ft máx 2 pares 9 10 100 m 328 08 ft máx Recomendaciones SMA SLA Instalar el módulo a distancia de los cables de transmisión informática o d...

Страница 13: ...ta ningún tag parpadeo de la LED antena color RFON 200 ms por defecto azul RFOFF 200ms Si detección de cualquier tag la LED antena encadena la secuencia color RFON por defecto azul color DETECCIÓN por defecto naranja durante 200ms y después LED OFF Si detección de un tag de configuración la LED antena encadena la secuencia color RFON por defecto azul color DETECCIÓN por defecto naranja durante 200...

Страница 14: ...mural orientable consultar el Manual de instalación del KFX UHF 08 Kit de fijación mástil orientable consultar el Manual de instalación del KFX UHF 09 O Fijación directamente en un muro Tornillo Ø4x35 acero inoxidable recomendado Conexión antenas SMA Es obligatorio conectar una antena al puerto RF 1 lo más cercano de las LED Puerto RF 1 4 longitudes de cables serializables están disponibles 1 5 m ...

Страница 15: ...r 75 x 75 mm 0 79 x 0 79 in tornillo M4x12 Acero inox suministrados en el kit de fijación Dos tipos de fijaciones posibles Kit de fijación mural orientable consultar el Manual de instalación del KFX UHF 08 Kit de fijación mástil orientable consultar el Manual de instalación del KFX UHF 09 Conexión antena s SLA Cables antenas SMA SLA Los cables de antena tienen 1 conector macho y un conector hembra...

Страница 16: ...porcionar una protección razonable contra las interferencias nocivas cuando el equipo se utiliza en un entorno residencial Este equipo genera utiliza y puede emitir frecuencias de radio y si no se instala y utiliza de acuerdo con las instrucciones puede crear interferencias nocivas que perturben las comunicaciones de radio Sin embargo nada puede garantizar la ausencia total de interferencias en un...

Отзывы: