Installation procedure 

LXE reader – Type B (connector) & C (cable) – ISO2 & Wiegand 

 

 

© STId 2005 – NI1004X02 - Ed. 08/08/05

 

 

 1

••••

 Wiring diagram : 

  
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

2

••••

 Recommended cables :  

 

Use  a  multi-conductor  cable,  pair  shielded.  When  power  is 
supplied with the same cable we recommend:  

 

 

 
1 pair AWG24 for up to 30 m 

1 pair AWG35 for up to 50 m 

2 pairs AWG24 for up to 60 m 

2 pairs AWG35 for up to 100 m 

3 pairs AWG24 for up to 100 m 

 

 

3

••••

 Pull-ups resistors 

 
If pull-up resistors for data signals are not present on the host 
unit  to  which  the  reader  is  connected,  it  will  be  necessary  to 
activate the built-in pull-up resistors of the reader. This is to be 
done as shown on the wiring diagram, using jumpers 3, 4, and 
5 to select the appropriate tension.  
 

4

••••

 Buzzer 

The buzzer gives an indication of correct read, not depending 
on the eventual authorizations or access rights given to a card. 
It will emit a brief sound as soon as a card or tag is read. It is 
possible  to  shut  it  off  by  removing  the  jumper  located  just 
nearby the buzzer.  
 

5

••••

 Led 

The led is bicolor (red/green). When the reader is powered on, 
it is amber (red+green). It can be driven by the remote system 
to light it either red or green, by bringing a 0V respectively on 
the red or green inputs of the reader’s connector.  
 

6

••••

 « Mode » input. 

By  default,  when  this  input  is  not  connected,  the  reader  will 
automatically  delay  the  transmission  of  the  code  every  2 
seconds when a card is left in the reading field. If a new card is 
shown  to  the  reader  before  this  time  laps,  its  code  will  be 
transmitted immediately.  
When  connected,  this  input  cancels  the  delay  in  the 
transmission  rate  of  a  same  card  left  in  the  reading  field.  In 
other word, the reader will transmit the code as fast as it can. 
 
 
 
 
 
 

 
 
 
To  cancel  the  delay,  connect  the  “Mode”  input  with  0V  as 
shown below:  
 
 
 
1. Power off the reader.  
2. Connect the input Mode to 0V.  
3. Power on the reader.  
 
 

  Check  if  the  reader  is  operating  properly  by  presenting  a 

card. The reader should then beep quickly on each reading.  

4.  To  come  back  to  the  initial  configuration,  power  off  the 
reader, then unplug the wire between “Mode” and “0V”. Power 
the reader on. Now, when a card is left in the reading area, the 
reader will beep only every two seconds.  
 

7

••••

 Installation 

1. 

Connect the reader 

2. 

Test the reading and communication. 

3. 

Attach the reader on the wall.  

4. 

Install the screw caps.  

 

Caution:  Screw  caps  are  made  to  be  hard  to  remove 
once  installed.  We  recommend  making  all  the  tests 
before installing them.  

 

8

••••

 Precautions for installation 

 

Beware, never pull the cable of the LXE C type reader. It 
is not designed for resting to harsh constraints. 

 

Power supply tension at the reader’s connector should be 
strictly comprised between 10.5V and 15V.  

 

Keep the reader away from computer or power cables as 
much  as  possible.  They  can  generate  an  electrical 
perturbation  that  is  function  of  their  proximity  and 
radiation level.  

 

Distance  to  respect  between  two  readers:  parallel  plan: 
30 cm – Same plan : 40 cm – Perpendicular : 25 cm. 

 

If the reader is mounted on a metallic surface it can affect 
the  reading  distance.  To  get  the  maximum  reading 
distance, the reader should be installed at no less than 7 
cm from any metallic surface.  

 

Variant B 

(With connector) 

Variant C 

(With cable) 

ISO 2 

2X 

Wiegand 

3X 

Brown 

0V 

0V 

Red 

+12 VDC 

+12 VDC 

Grey 

Code 

Data 0 

Blue 

Data 

Data 1 

Yellow 

Clock 

Clock 

White 

Mode 

Mode 

Green 

Green Led  Green Led 

Rose 

Red Led 

Red Led 

0V

+12V

Code / Data 0

Data / Data 1

Clock

Mode

0 1 2

 

3

 

4

 

5

 

6

 

7

 

Power

 

12V / 0,5A min.

 

Data  signals

 

LED Commands

 

Buzzer

 

 

 

: Jumper

 

 open = Off /  closed

 

 = On

 

Pull- ups at

 

 +5V

Pull- ups

 

 

at

 

 +12V

 

JUMPER DETAILS

 

 :

 

1 & 2 =  Buzzer  : Open = Off /  Closed

 

 = On

 

3 & 4 =  Selects pull-

 

ups at

 

 5V

4 & 5 =  Selects pull-

 

ups

 

 

 

at 12V

3, 4 et 5 ouverts =  No pull-up

 





 
 

 

 

 

 