![STI Theft Stopper STI-6200 Series Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/sti/theft-stopper-sti-6200-series/theft-stopper-sti-6200-series_install_1376337001.webp)
Theft Stopper
®
1.
Remove security screw
with provided wrench.
2.
To remove cover from base,
push with thumb to separate
(as shown).
3.
Select volume setting by
shifting black cap.
4.
Unwrap battery and connect. Insert 6” service
cables into base to silence. Cable should not
exceed past base edge.
7.
Apply language label if desired.
2
1
2
#8-10 x 7/8 in.
PLASTIC ANCHOR
(4) PROVIDED
POLYCARBONATE BASE
PRINTED CIRCUIT BOARD
VOLUME CONTROL JUMPER
SEE AUXILIARY VIEW
KIT-H19016 TAMPER WRENCH
#8-32 x 3/8 in.
TRUSS HEAD TAMPER SCREW
KIT-18015-9 DEACTIVATION/SERVICE CABLE
#8 x 1 in. SCREW
(4) PROVIDED
9 VOLT BATTERY
POLYCARBONATE COVER
CIRCUIT BOARD
CAP ON 2 RIGHT PRONGS
FOR HIGH VOLUME (DEFAULT)
CAP ON 2 LEFT PRONGS
FOR LOW VOLUME
5.375 in.
(137mm)
2 in.(51mm) DEPTH
VIEW SHOWING BATTERY REPLACEMENT
9 VOLT BATTERY
VIEW SHOWING JUMPER LOCATION
FOR VOLUME SETTTINGS
OPTIONAL LABEL
VIEW SHOWING BATTERY
REPLACEMENT
9 VOLT BATTERY
OPTIONAL LANGUAGE LABEL
HORN/SOUNDER
95/105dB
5.375 in.
(137mm)
2 in.(51mm) DEPTH
16”-18” CABLE
CABLE
VOLUME
5.
Position base. Mark and drill four (4) holes 1”
(25mm) deep. Using plastic anchor, drill 3/16”
(4.5mm). Install into wood or steel: drill 9/64”
(3.5mm). Mount using (4) M4 x 25mm screws.
NOTE: Cable is approximately 16” – 18” long.
6.
Replace cover, snap lid from top,
secure with security screw.
MOUNTING
HOLES
MOUNTING
HOLES
KIT-18015-9
DEACTIVATION/SERVICE CABLE
MOUNTING
HOLES
MOUNTING
HOLES
KIT-18015-9
DEACTIVATION/SERVICE CABLE
Install
STI-6200 Series