5
1 0 0 0 0 0 BUZZ
2 1 0 0 0 0 SLOW ON/OFF
3 0 1 0 0 0 SLOW SIREN
4 1 1 0 0 0 3 BEEP/PAUSE/REPEAT
5 0 0 1 0 0 UFO FAST
6 1 0 1 0 0 FAST SIREN
7 0 1 1 0 0 #5 FAST
8 1 1 1 0 0 #2 MEDIUM
9 0 0 0 1 0 #5 MEDIUM
10 1 0 0 1 0 SWOOP MEDIUM
11 0 1 0 1 0 #3 MEDIUM
12 1 1 0 1 0 BUZZ TONE
13 0 0 1 1 0 STEADY FAST
14 1 0 1 1 0 SWOOP SLOW
15 0 1 1 1 0 CONTINUOUS
16 1 1 1 1 0 FAST REPEAT
17 0 0 0 01 STANDARD ALARM
18 1 0 0 0 1 #3 FAST
19 0 1 0 0 1 #5 SLOW
20 1 1 0 0 1 FAST BEEP
21 0 0 1 0 1 SOUND A
22 1 0 1 0 1 SOUND B
23 0 1 1 0 1 SOUND C
24 1 1 1 0 1 SOUND D
25 0 0 0 1 1 SOUND D LOUD
26 1 0 0 1 1 SOUND E
27 0 1 0 1 1 SOUND F
28 1 1 0 1 1 SOUND G
29 0 0 1 1 1 SOUND H
30 1 0 1 1 1 #4 LOW
31 0 1 1 1 1 SOUND K
32 1 1 1 1 1 CONTINUOUS FAST
1
ALARM TIMING
VOLUME
STROBE TIMING
ON
OFF
1
2
3
4
5
0
15 seconds 1 1 1 1 High
30 seconds 1 0 1 0 1
60 seconds 0 1 0 1 Low
Continuous 0 0 0 0 0
1 = ON
0 = OFF
STEP 3 - ALARM TONES - S1
STEP 4 - ALARM TIMING AND VOLUME - S2
S1
ALARM TONE
S2
ALARM TIMING
STROBE TIMING
VOLUME
LED QTY 10
LOW BATTERY
INDICATOR LED
TERMINAL STRIP
TAMPER SWITCH
(REAR VIEW)
WIRE ENTRY
BATTERY
BATTERY CABLE
SIREN
O
O
1 2 3 4 5
1 2 3 4 5
ALARM
TIMING
1 2
3 4
5
VOLUME
STROBE
SIREN
*
Factory default settings
*
*
STEP 2 - ELECTRONIC SETUP - SELECT ALARM TONE
AND TIMING SEQUENCE
NOTE:
Select-Alert must be on a flat surface and lens must be
installed or the tamper switch will trigger the alarm.
NOTE:
Sound may be disabled by clipping
wires to the siren. THIS WILL VOID ALL
WARRANTIES. Remove two screws on cir-
cuit board; leave enough length of wire
to possibly reattach in the future. Then
insulate wires to prevent shorting to
electronic components.
O
O
WIRES TO SIREN