background image

This  information  is  designed  to  help  suitably  qualified 

personnel  install  and  operate  STI  Safety  Switch  equipment. 
Before  using  this  product,  read  this  guide  thoroughly  along 
with  any  relevant  European  and/or  National  standards  e.g. 
Machinery  Directive  89/392/EEC  and  it’s  amendments, 
Provision and Use of Work Equipment Regulations.  

Further information can be obtained from   

STI 

KEEP THIS GUIDE FOR FUTURE REFERENCE  

The MF Series safety switches are electronically operated 
non-contact safety switch for use in machine guarding 
applications.  

The non-contact operation makes the MF-2 easy to install 
and tolerant to misalignment, providing a simple reliable 
solution to machine guard interlocking. 

The electronic operation provides additional security and  

single point switching. This leads to a more reliable and 
secure long term safety solution.  

The switch and actuator are IP67 rated and can be used in 

wet or dusty environments.

 

CE 

Complies  with  the  relevant  sections  of  the  CE 

marking directive.  

UL 

Pending 

EUROPEAN DIRECTIVES 
Machinery Directive 98/37/EC  

Low Voltage Directive 73/23/EC 

Electromagnetic Compatibility Directive 89/336/EC  

EUROPEAN STANDARDS 
EN292 

Safety of Machinery 

Basic concepts, general principles for design. 

EN 60204  Safety of Machinery 

Electrical equipment of machines. 

EN 954-1  Safety of Machinery 

Safety related parts of controls systems  

EN 1088 

Interlocking devices associated with guards. 

EN  

60947-5-3 

Safety of Machinery 

Specification  for  low  voltage  switchgear  and 
control gear. 

Interlocked guards where additional security required. 
Door locking is not required.  

Food and Beverage packing/filling systems 
Diary Pharmaceutical Paper Industry  
Can Forming and Filling, (Aluminum, Steel, Plastic)  
Semiconductor Manufacture/Assembly. 

Description 

A  Declaration  of  Conformity  can  be  obtained  from  the 

OMRON STI Web Site: WWW.STI.COM 

The MF-2 is designed for use with ‘low inrush current’ safety 
relays like the OMRON SR 131A and SR 231A. Maximum 

switching for long life performance is 500mA.   

When installed on a machine guard, power is applied, and 
the switch and actuator are within the specified operating 
range (See table on page 4 for switching distances). The 

Normally Closed 

Contact will be closed and the Normally 

Open 

Contact will be open. The dual color LED will be 

GREEN.  When the actuator moves out of the operating 

range, the Normally Closed 

Contact will open the Normally 

Open 

Contact will close. The dual color LED will be RED. 

The MF-2 safety switch and actuator have a 10mm switching 

distance and can approach each other from most angles. 
When the switch is closed the targets on the printed face of 

Operation 

CAUTION

 

Applications 

Approvals 

Declaration of Conformity 

MF-2

 

Pending 

Safety, 

Technology 

& Innovation 

MF Series

Operating Instructions for MF-2 Safety Switches

 

the switch must be aligned. To Assure proper operation of 
the switch a minimum distance or gap of 2mm must be 
maintained between the Switch and actuator. See 
Mounting Section for details.

Rev. 3.09

Содержание MF Series

Страница 1: ...associated with guards EN 60947 5 3 Safety of Machinery Specification for low voltage switchgear and control gear Interlocked guards where additional security required Door locking is not required Food and Beverage packing filling systems Diary Pharmaceutical Paper Industry Can Forming and Filling Aluminum Steel Plastic Semiconductor Manufacture Assembly Description A Declaration of Conformity can...

Страница 2: ... DIMENSIONS MOUNTING The MF 2 safety switches can approach each other from most angles When the guard is closed the targets on the printed face of the switch and actuator must be aligned EN 1088 Provides some mounting suggestions see example opposite When fixing the safety switch to a sliding door A ensure that when the door is opened B it is not easily accessible helping prevent the system being ...

Страница 3: ...les of this type of relay are listed below OMRON STI SR131A SR231A See diagram below OPERATION 1 POWER ON GATE CLOSED When the switch has power and the actuator is in place the LED will be GREEN The Normally Closed contact will be closed and the Normally Open contact will be open 2 POWER ON GATE OPEN When the switch has power and the actuator is out of range the LED will be RED The Normally Closed...

Страница 4: ...es are described as normally closed N C i e With the guard closed actuator in place and the machine able to be started In the interest of product development specifications are subject to change without notice Document No 563 400 v3 Internal Fuse N O N C 1Amp Fast Acting External Fuse Customer Supplied AC DC 500mA Fast Acting IP Rating IP67 Vibration Shock 50 100Hz 10g Operating Temperature 10 to ...

Страница 5: ...stems Machine Automation Controllers MAC Programmable Controllers PLC Operator interfaces HMI Distributed I O Software Drives Motion Controls Servo AC Drives Motion Controllers Encoders Temperature Process Controllers Single and Multi loop Controllers Sensors Vision Proximity Sensors Photoelectric Sensors Fiber Optic Sensors Amplified Photomicrosensors Measurement Sensors Ultrasonic Sensors Vision...