16
A
C
B
B
Assembly of the solar collectors
To avoid a cutting/processing of the upper
tile row it is recommended to uncover the
upper tile row as well based on measure
A.
Also consider that the measure A is
metered from top to bottom.
construction lath KVZ 40 x 60 mm
1440104 FKF 200/240/270 V L= 1,2 m
1440112 FKF 200 H L= 1,7 m
1440103 FKF 240 H L= 2,1 m
1440105 FKF 270 H L= 2,5 m
3000155 Chipboard screw
5x100 mm
For precise placement of the construction
lath, please use the measurements in the
table below.
If the fastening point is on +/- 5 cm the
impact region within the cross battens
you have to introduce an additional
batten according to the technical rules of
the attachment point is moved.
Collektor type
measure
A *
measure B
measure C
for each add. row
FKF 200 V
2,08 m
minimum 20 cm
9 -15 cm
measure
A + 1,82 m
FKF 240 V
2,33 m
minimum 20 cm
9 -15 cm
measure
A + 2,07 m
FKF 270 V
2,60 m
minimum 20 cm
9 -15 cm
measure
A + 2,34 m
FKA 200/240/270H
1,43 m
Minimum 20 cm
9 -15 cm
measure A + 1,17 m
* The declared values for measure A are valid for single row installations.
First uncover the tiles in the area where the collectors will be mounted.
The total width results from: Field width (page 8) + 40 cm
The total height results from: Field height (page 8) + 53 to 62 cm
Place the stop lath(s) to prepare the assembly of the collectors.
Ensure that the stop lath is fixed parallel and straight (line mark) to the counter lath.
Pay attention to stringently stick to the measure A of the assembly of the construction lath!
Содержание FKF 200
Страница 1: ...Assembly instructions Solar collectors FKF 200 240 270 Roof integrated installation...
Страница 43: ...43 Initial operation Schematic drawing of the system construction and piping scheme...
Страница 44: ...44 Initial operation Schematic drawing of the system construction and piping scheme...
Страница 45: ...45 Notes Initial operation...
Страница 46: ...46 Notes Initial operation...