19
Assembly of the plain tile clamps
with lead
Assembly of the plain tile clamps
with lead
Fixation of the roof-tile clamp with two screws 5 x 60 mm.
Screw the lower one into the tile lath and the upper
one into the tile clamp support.
Completely mounted roof-tile clamp with lower lead sheet.
The tile clamp must have a minimum distance of 5 mm to the
underlying tile.
Mount the upper lead sheet while placing the lead laterally
under the tiles.
Make sure that the corners are bent under the tile on both sides
to avoid a slipping off.
Covering of the upper tiles.
Completely mounted roof-tile clamp.
Further roof-tile clamps in one row must be adjusted
exactly (e. g. by a line mark).
Make sure that the corners of the lead sheet are bent under the
tile to avoid a slipping off.
1410005 Roof-tile clamp V2 plain tile
with lead