The motor requires standard AC input (unless an alternate voltage has been
specified). All connections are made to the electrical box on the side of the
unit (audience left).
There are several switch controls available. Follow the installation
procedure for the type of switch control you will install.
General suggestions for wiring:
Soldering is recommended.
The use of wire nuts is acceptable.
Stewart Filmscreen supplies a short electrical connection wire that is fitted
with a Molex motor connector. You will connect the harness (pigtail) to the
incoming AC Romex or service cord by wire nuts. Refer to Figure 3 for an
illustration of the electrical connection on the side of the screen unit.
1. Feed the incoming AC Romex or service cord through the Romex
connector on the housing.
2. Connect the pigtail with wire nuts on the inside of the housing.
The AC connection to this pigtail should never be made on the
outside of the enclosure as this would violate NEC electrical code
and UL standards.
Visionary Electriscreen: Owner’s Manual
5
S
TEP
2. E
LECTRICAL
H
OOK
-
UP
Caution
Professional techniques need to used when making any
electrical connection. A qualified electrician should perform
these procedures.
Be sure to follow all standard safety procedures for
installing electrical devices.
Do not disassemble or alter the configuration of the motor
or the unit's electrical connections. This may cause injury to
you or damage to the product.
The electrical connection should be made only to the type
of power source indicated on the marking label.
Figure 3:
Electrical connection
Romex
Connector
Electrical
Source
Molex
Connector