Installing the high voltage switch control (standard)
A standard 3-position wall switch is supplied. The high-voltage control is
connected to the electrical source. It alternates directions of screen motion by
means of the hot lead, using the 3-position switch.
Preparing the connection
Before making the electrical connections, you need:
An available AC constant power source
One 4-conductor romex per connection or motor connector cable or
one 8-conductor romex for two connections
Making the connections
The diagram in Figure 7 illustrates the connections.
1. Connect the wall switch to the AC constant power source.
2. Connect the wall switch to the screen unit’s electrical box.
ElectriMask Electriscreen: Owner’s Manual
7
AC Power
Source
Screen Switch
Mask Switch
DOWN-Black
UP-Red
Line (Hot)
COMMON-White (Neutral)
GROUND-Green
Note:
You need to make the connections for each switch.
Figure 7:
High voltage control wiring diagram