1) No power.
•
Check the plug socket, cable, line and plug, where appropriate, have repaired
through electrical specialist.
•
Any of the parts are defective, such as On/Off switch /motor etc. (please contact
service agent).
•
Motor overloaded, the motor circuit breaker has tripper.
•
Turn off the appliance “0/OFF”.
•
Allow the device to cool down for 5 minutes.
•
Switch on the device and put it into operation again. If the malfunction occurs
repeatedly, have the device checked by the customer service.
2) The high pressure washer operates intermittently.
•
Power cable is damaged.
•
Internal loose electrical connection.
•
On/Off switch defective(please contact service agent).
•
Nozzle is clogged. Clean dirty from the nozzle opening using the nozzle cleaner
provided .
3) No or only little pressure is built up.
•
Check if there is any air in the system, if so, please ventilate the machine! Run the
machine without the high-pressure hose connected until water starts leaking
without bubbles. Re-attach the high-pressure hose.
•
Check all inlet pipes leading to the pump for leaks or clogs.
•
Check the setting on the hand-held spray gun.
4) Great pressure varieties.
•
Clean the high pressure jet nozzle
•
Check the water inlet pressure.
5) Machine pulsating
•
Check if there is any air in the hose or pump,allow machine to run with open
trigger until regular working pressure resumes.
•
Check if there isinadequate supply of mains water,avoid using long, thin hoses(min
1/2’’).
•
Check if nozzle partially blocked or water filter blocked,clean the nozzle or filter.
•
Check if the hose kinked,straighten out hose.
6) Machine is leaking.
•
Please contact the authorized agent.
•
Seals worn of spear ,3in1 nozzle or inlet nozzle
We additionally offer the seals of 3in1 nozzle, spear and inlet nozzle, replace with
the new seals.
•
Seals worn of other parts.
Please contact the authorized agent.
9. TROUBLE-SHOOTING
158
EN
EN
Содержание 150HR EPW.4
Страница 15: ...10 EXPLODED VIEW 159 EN ...