Operating instructions (Version 0)
58
ST 1075
7.4.2 Electrical diagram for control box
For an overview of the electrical components and the electrical diagram, refer to
section
A.6 "Electrical diagram control box" on page 86
7.4.3 Hydraulic components
For an overview of the hydraulic components and the hydraulics diagram, refer to
section
A.3 "Hydraulic scheme" on page 80
7.5
Troubleshooting
7.5.1 Warnings
Various functions can be locked out when there is a warning. This is shown on the
screen as follows:
The table indicates how the system can then be brought back to its normal status.
Figure 7.5
Warning
Table 7.2
Warnings
Code
Screen text
Possible cause
Solution
01
Down stop limit
exceeded
Obstacle under the
columns
Raise a little and remove
obstacle
02
Maximum
height
reached.
One of the columns
has reached its
highest position.
System can be lowered
normally.
03
Maximum
programmed
height
reached.
One of the columns
has reached the
highest position as
defined in the
software.
System can be lowered
normally.
04
Crush limit
reached.
Lowering to below
2.5" is not possible
with a remote control.
Can be lowered further by
using the buttons on the
column.
WARNING 1
Down stop limit
exceeded
Содержание ST1075-FBF
Страница 21: ...Safety Operating instructions Version 0 21 ST 1075 2 Figure 2 2 Safety and warning labels ...
Страница 78: ...Operating instructions Version 0 78 ST 1075 A 2 Hydraulic unit Figure A 2 Hydraulic unit ...
Страница 85: ...List of parts and appendices Operating instructions Version 0 85 ST 1075 A Figure A 5 3 Control box ...
Страница 90: ...Operating instructions Version 0 90 ST 1075 A 9 Label locations Figure A 9 Label locations ...
Страница 100: ...Operating instructions Version 0 100 ST 1075 Date Remarks Name of mechanic Initials of mechanic pass ...