SETTINGS ADJUSTMENT
Adjusting the sensor range with the remote control
This faucet was supplied with Stern’s
new Self Adjusting Sensor. The ideal
sensor range for the specific location
will be set automatically.
Only if necessary
, use the remote
control to adjust the sensor range as
follows:
Shut off the water supply. In order
to adjust the sensor with the remote
control hold the remote control straight
in front of the sensor in a distance of
about 4” (10cm). Choose the function
you want to adjust by pressing once
on one of the function buttons. After
pressing once on a specific function
button, a quick flashing of the red light
at the front of the sensor will occur. At
this stage, you can change the setting
by pressing the (+) or the (-) buttons, every push will increase or decrease one
level. After finishing the adjustment, turn the water supply back on.
DETECTION RANGE:
Press + to increase detection range and – to
decrease the detection range of the sensor.
1
4
3
2
5
8
7
9
6
1
Note:
Once you have changed the detection range with the remote control,
this distance will be remembered by the sensor, even if the power source is