STEP 12:
Set the Timer Control (Figure 4a) by rotating the Skipper Wheel (Figure 4a) so the red pointer
is directly over day 1. Select the days when backwashing will occur by sliding the metal tabs in
or out. IN indicates no backwashing will occur on that day, OUT indicates that backwashing
will occur on that day.
Factory setting is to initiate backwash every third day.
Set timer so
the next backwash will not occur for at least 24 hours. This allows the media to become fully
saturated and prevents loss of media to drain during the first backwash.
For the OXY3E proceed to STEP 13.
STEP 13:
Set the current time of day. For the OXY3 start by depressing the red Time Set Button (Figure
4a) and turning the 24 Hour Gear (Figure 4a) to the desired time (note AM and PM).
For the OXY3E refer to OXY3E Setting Time of Day on page 12.
STEP 14:
Time of Regeneration is factory set to 1:00 A.M. Ensure time of regeneration does not
interfere with other water treatment equipment. To adjust the time of regeneration for OXY3:
a) Unplug control valve from electrical outlet
b) Locate three screws (Figure 4b) behind the Manual Backwash Knob (Figure 4a) by
pushing the red Time Set Button (Figure 4a) and rotating the 24 Hour Gear (Figure
4a) until each screw appears in the cut out portion of the Manual Backwash Knob.
c) Loosen each screw slightly to release pressure on the 24 Hour gear time plate.
BACKWASH TIMER
CONTROL
FIGURE 4a: Timer in Service Position
FIGURE 4b: Adjusting Time of Regeneration