Sterling HWRAF075N Скачать руководство пользователя страница 2

W

ARNING:

 

ALL 

PERSONS 

USING 

THIS 

EQUIP

MENT 

MUST 

READ 

AND 

UNDERST

AND 

ALL 

INSTRUC

TIONS. 

FAIL

URE 

TO

 DO 

SO MA

Y RESU

LT

 IN SERIOUS INJU

RY

 OR DEA

TH. USERS SHOULD 

BE 

FA

MILIAR WITH 

PERTINENT 

REGULA

TIONS 

GOVERNING THIS

 

EQUIP

MENT

. ALL 

INDIVIDU

ALS WHO 

USE THIS 

PRODU

CT

 M

UST 

BE 

PROPER

LY

 INSTRU

CT

ED 

ON 

HOW 

TO

 USE 

THE 

DEVICE. 

AVOID 

CO

NT

AC

WITH 

PHY

SICAL 

HAZARDS 

(T

HERMAL, 

CHEMICAL, 

ELEC

TRICAL, 

ET

C.). MAKE ONL

Y CO

MP

AT

IBLE 

CO

NNEC

TIONS.

Compliance: OSHA

 1926.502 & 1910.66 

DO NOT REMOVE  

Stainless Steel, 

Aluminum, Zinc Plated Copper

drill

 .75”

Ø  

(A)”  

min from an

y edge  

(B)”  

TAP!!!  

DO NOT REMOVE 

WARNING LABEL!  

May be used as an anchor point for a leading edge 

restraint system.  See optional anchor points below for 

example. The use of two anchors  is not required for 

leading edge restraint systems unless otherwise speci-

fied by the manufacturer.  

WORK SURFACE  

OPTIONAL 

(ANCHOR POINTS)  

WORK SURFACE  

(ANCHOR POINT)  

Concrete must be  

3000-psi or higher and  

fully cured. Installation  

location to be approved  

by a qualified person.  

MINIMUM CLEARANCE 3ft (1m)  

DECK/FLOOR/GROUND LEVEL  

W

ARNING!!! SWING F

ALLS M

AY OC

CUR 

WHEN 

THE 

W

ORKER IS NO

T DIREC

TL

Y UNDER ANCHOR POINT

.  

All products subjected to fall arresting forces should be removed  

from service immediately!  

1.25” (31mm)

   

Cleaning Bushing  

5” (127mm)

   

End Termination

   

Stop Sleeve 

   

11.5” (293mm)

   

Heavy Duty Return Wire

   

Spring

Trigger  

Anchor Loop

   

3” (76mm)

2” (50.8mm)

   

Spoon   

Main Cable  

DRILLING & INSTALLATION INSTRUCTIONS: 

1.

 Drill a .75” (20mm) diameter hole at least 3.5” (89mm) deep. The drilled hole must be straight and perpendicular         

     to the surface. Make sure the hole is of uniform diameter and free of peaks and valleys on the inner wall. 

2.

 Blow hole clean with compressed air. 

3.

 Always inspect the hole carefully when reusing a previously drilled hole. 

4.

 When placing anchor, place your thumb inside the anchor loop and your first two fingers around the trigger.          

     Squeeze fingers and thumb together till the trigger and spring fully compress. 

5.

 Insert unit at least 3” (76mm) deep into hole and release the trigger. Do not force. 

6. 

Set the unit with a slight tug on the anchor loop. 

7.

 The stop sleeve must always be partially inserted into the hole.  

REMOVAL INSTRUCTIONS:  

1. 

When removing anchor, place your thumb inside the anchor loop          

     and your first two fingers around the trigger. Squeeze fingers and      

     thumb together until the trigger and spring fully compress. 

2.

 While squeezing the trigger, pull the anchor out of the hole. 

3.

 If the anchor becomes stuck, insert a punch, screwdriver or other          

     object into the hole until it touches the top of the cleaning bushing. 

4.

 Lightly tap with a hammer, making sure the tool is touching the top         

     of the cleaning bushing, while squeezing the trigger.  The cleaning         

     bushing should be easily visible at the edge of the hole. 

5.

 If tool was required to remove the anchorage, inspect thoroughly    

     for damage after removal. If damage is found, remove from service  

     and destroy immediately.  

Swage

   

*The user shall be equipped with 

a means of limiting  the maximum 

dynamic forces exerted on the 

user during the arrest of a fall to a 

maximum of 8 kN (1800-lbf). 

In the 

EU these forces must be limited  

to 6 kN (1350-lbf).

Compliance: OSHA 1926.502, OSHA 1910.66, ANSI Z359.1(07), ANSI Z359.7(11)

3/4”

 Remo

vable 

Concr

et

e A

nchor

M

odel: HWR

AF075N

Ba

tch# RB5-

XX

X

MFD: MM/Y

YY

Y

Stainless Steel, Aluminium, Zinc Plated Copper, 7x19 Aircraft Cable

Pat # 7,357,363 B2 / 7,011,281 B2 / US 6,729,821 B2

WARNING:

 

ALL PERSONS USING THIS EQUIPMENT MUST 

READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO 

SO MAY RESULT IN SERIOUS INJURY OR DEATH. USERS SHOULD 

BE FAMILIAR WITH PERTINENT REGULATIONS GOVERNING THIS 

EQUIPMENT. ALL INDIVIDUALS WHO USE THIS PRODUCT MUST 

BE PROPERLY INSTRUCTED ON HOW TO USE THE DEVICE. AVOID 

CONTACT WITH PHYSICAL HAZARDS (THERMAL, CHEMICAL, 

ELECTRICAL, ETC.). MAKE ONLY COMPATIBLE CONNECTIONS.

(207) 282-2550

HOLE DRILLING REQUIREMENT CHART

(A)” Minimum distance from edge/corner (B)” Concrete thickness

6” (15.3 cm)

12” (30.5 cm)

12” (30.5 cm)

5” (12.7 cm)

PERFORMANCE: 

Static Tensile Strength: 

5000-lbf  (22kN)  

Maximum Capacity: 

One worker with  

max weight of 310-lbs when used as a  

single point anchorage connector for  

personal fall arrest or restraint system

DIMENSIONS: 

Weight:

 .44-lbs (200g) 

Length: 

11.5” (293mm) 

Diameter 

.75” (19mm)  

REGULATORY COMPLIANCE:

  

ANSI Z359.1-2007, ANSI Z359.7-2011 

OSHA 1926.502, OSHA 1910.66,                  

COMPONENT MATERIALS:  

Aluminum:

 Trigger 

Aircraft Cable: 

Main Cable, Activator Wire 

Polyurethane: 

Loop Cover 

Stainless Steel:

 Cone, Spoons, Stop Sleeve 

Zinc Plated Steel: 

Spring 

Zinc Plated Copper: 

Swage  

90º

90º

PROPER LOADING

Good

Best

See Spoon Orientation

Good

See Spoon Orientation

*Best practice for spoon orientation

when loaded 90º to hole.

SPOON ORIENTATION

Best

Ok

Load

Load

=

=