Thank you for choosing the Acuatic Vacuum 12 B steriliser from Sterling Sterilisers. We are confident that you have
purchased the finest steriliser of its type which will provide you with many years of efficient, reliable service.

Features

Fast -

cycle times are between 12 and 35 minutes from start to finish not including  drying - dependent on cycle

choice and loading

Simple to use -

easy to understand colour touch screen display

Easy close and easy open door -

push to close with vacuum assistance, touch button opening

Inbuilt Securilog data logger -

to encrypt and record cycle details onto a memory card

Separate internal clean and used water reservoirs -

water is only used once per cycle to ensure cleanliness

Easy to service and maintain -

keeps downtime and maintenance costs to a minimum

No internal heating element -

makes for easy cleaning of the chamber

N-type cycle -

a fast, non vacuum cycle for solid unwrapped instruments

B-type cycle -

a vacuum cycle for solid, hollow, tubular or porous loads, wrapped or unwrapped, pouched or not

Low energy consumption per cycle -

keeps running costs to a minimum

Low water consumption per cycle -

keeps water production or purchase costs to a minimum

No rust construction -

structural parts are manufactured from stainless steel  or aluminium

Impossible to overheat -

innovative engineering eliminates downtime due to overheating

Easy water fill -

just pour into the filling spout

Clean water auto fill -

connects to an external water supply for automatic filling

Easy water drain -

simple plug in drain hose

Used water auto drain -

 connect a tube to the rear of the steriliser for automatic draining

Self monitoring -

an automatic control system continuously monitors cycle parameters to ensure effective, reliable

and complete sterilisation

Parts Supplied with the Acuatic Vacuum steriliser

These instructions
Four trays, tray rack and tray handle
Two drain tubes
Drying rack if the steriliser is supplied for use in the dental market
SD memory card and USB adaptor

Guarantee

No other steriliser manufacturer offers the security and assurance of a guarantee quite like the onesupplied by Sterling
Sterilisers. We're so confident in the quality and reliability of our product that each of our distributors provide a one
year parts and labour guarantee and a five year, fully transferable, unlimited usage parts guarantee. For full details of
the guarantee see

www.sterlingsterilisers.com

.

Pressure Vessel

The parts of the steriliser that are subject to steam pressure comply with the Pressure Systems Safety Regulations
2000.

1

Acuatic Vacuum steriliser

Introduction

Содержание Acuatic Vacuum 12 B

Страница 1: ...Sterling Sterilisers Acuatic Vacuum 12 B User Instructions...

Страница 2: ...n EC No 1882 2003 0086 indicates that the Notified Body employed to check conformation with the above is BSI This symbol indicates that the number next to it is the serial number of the steriliser Thi...

Страница 3: ...Logger Daily Maintenance 4 DailyTesting 4 Weekly Testing 4 Servicing 4 Annual Inspection 4 Annual Testing 4 Getting Started GettingStarted 5 Filling 5 Water Quality 5 Draining 5 Options 5 Operation S...

Страница 4: ...onstruction structural parts are manufactured from stainless steel or aluminium Impossible to overheat innovative engineering eliminates downtime due to overheating Easy water fill just pour into the...

Страница 5: ...ising Drying 138 C 134 C 1 0 2 Pressure bar 1 Time Air removal and heating Drying Sterilising B type A door seal B chamber with tray rack and trays C water filling spout D touch screen display E clean...

Страница 6: ...d instruments the internal surfaces of the steriliser and the steriliser door may be hot Do not touch these parts until cooling has taken place and exercise care when handling just sterilised instrume...

Страница 7: ...is observed Weekly Testing Run the automatic air leakage test This test will show that the steriliser is capable of pulling and holding a certain level of vacuum The display will indicate a pass or f...

Страница 8: ...this is not recommended because of the risk of the heaters becoming scaled Draining When the used water reservoir is full the display will ask for it to be drained This will need to be done before the...

Страница 9: ...If the N type cycle is enabled you will be offered a choice of starting N type or B type cycles Processing When a cycle is running the display will show the cycle time elapsed the operating temperatu...

Страница 10: ...ep the Add shortcut to desktop checkbox ticked To import cycle data from the SD memory card to your computer run the Securilog application by double clicking the Securilog icon on your desktop Remove...

Страница 11: ...with the Medical Devices Directive 4 A Product Registration and Customer Survey form Please take the time to print this out complete it and return it to Sterling Sterilisers so that we can keep our re...

Страница 12: ...apped pouched or not Limits Design pressure 1 to 3 bar Design temperature 2 to 144 C Water Water used per cycle 200 to 700 ml Clean water reservoir volume 2 litres Used water reservoir volume 2 litres...

Отзывы: