Sterling Power Portable Battery Charger B121 Скачать руководство пользователя страница 7

Specifications 

Battery Load T

ester

.

Heavy duty leads and clamps.

125A

 test load. 

Suitable for 1 x 12V battery per test, for 

24-36V or larger simply split the battery 

bank split down to 12V sections for test.  

Battery from 200-1000 cold cranking 

(CCA). 

Battery from approx 30-140Ah rating. 

Indicates extent of battery sulphation / 

battery 

condition.

Battery voltmeter

.

High voltage load test safety trip at 

13V

Fast 10 second load tests (2 min wait 

between tests).

Digital Battery T

ester 

includes alternator and starter motor tests

  

What 

does 

the 

tester 

do?

Simply 

measuring 

battery 

voltage 

is 
not 

true 

indication 

of 
the 

state 

of 

battery

. A

 battery 

test 

has 

aspects 

to 
it: 

There 

is 

the 

voltage 

of 
the 

battery 

(which 

is 

rough 

indication 

if 

the 

battery 

is 

fully 

charged). 

Then, 

there 

is 

the 

ability 

of 
the 

battery 

to 
hold 

and 

deliver 

the 

power 

it 

has 

stored. 

I.e 
the 

voltage 

could 

show 

the 

battery 

is 

fully 

charged 

but 

the 

battery 

could 

be 
badly 

sulphated 

and 

useless. 

Y

ou 
need 

to 
test 

the 

voltage 

of 
the 

battery 

under 

heavy 

load 

condition. 

The 

load 

test

Depending 

on 
the 

size 

of 
the 

battery

this 

product 

adds 

very 

high 

load 

to 
the 

battery 

(125 

A). 

The 

battery 

should 

be 
able 

to 
deliver 

this 

load 

and 

hold 

the 

voltage 

up 
at 
the 

same 

time. 

If 

the 

battery 

is 

unable 

to 
deliver 

the 

load 

(and 

sustain 

it 

for 
this 

time 

frame) 

then 

the 

battery 

is 
either 

defective 

or 
simply 

not 

fully 

charged 

when 

the 

test 

was 

performed. 

This 

is 

why 

it 

is 

crucial 

to 
ensure 

the 

batteries 

are 

fully 

charged 

before 

the 

test 

is 

performed 

to 

eliminate 

that 

possibility

T

test 

simply 

connect 

the 

unit 

to 

12V 

fully 

charger 

battery

, adjust 

the 

CCA

 (cold 

cranking 

amps) 

on 
the 

screen 

up 

to 
999A, 

then 

press 

the 

load 

button 

and 

perform 

the 

10 
second 

test. 

The 

unit 

will 

inform 

you 

if 

the 

battery 

is 
good, 

weak 

or 
bad. 

 

The 

unit 

can 

also 

be 
used 

to 
measure 

the 

performance 

of 
the 

charging 

device 

(alternator 

battery 

charger) 

to 

inform 

the 

user 

whether 

the 

charging 

device 

is 

good, 

weak 

or 
bad.

1000 amps cold cranking battery

140 amp hr battery

125 amp load

                       Digital battery tester

                  Size mm                                                                                  W

eight         Part number

   280 L

 x 100 W x 120 D    630mm cable (handle to end of clamps)    1.1 kg            DBT125

   

Pure Sine wave inverters with USB and RCD version  

Pro 

Power SB (R) 

Pure Sine W

ave Inverters 

- w

ith 
T

win socket or built in 

RCD

-

 

adjustable between 

Neutral Earth Bonding

 

Option 1

T

win socket

adjustable between 

Centre tapped earth

and Neutral earth bonding

with USB charger

Optional remote control  

Option 2

Pre-wired 

RCD

Centre tapped earth &

Neutral earth bonded 

with USB charger

Optional remote control 

    

 Model                      Centre tapped Earth     Neutral earth bonded      Remote        W

eight      Size mm                 Cables             Part number

12V 300 watt 

T

win sockets          Interchangeable          between both            Optional extra     1.4 kg    190x85x210L

     1m DC 8 mm ring       SIB12300

12V 600 watt 

T

win sockets          Interchangeable          between both            Optional extra     2.2 kg    190x85x250L

     1m DC 8 mm ring       SIB12600

12V 1000 watt 

T

win sockets        Interchangeable          between both            Optional extra     2.0 kg    190x85x300L

     1m DC 8 mm ring       SIB121000

12V 1600 watt 

T

win sockets        Interchangeable          between both            Optional extra     3.6 kg    190x85x300L

     8 mm connection        SIB121600

24V 300 watt 

T

win sockets               interchangeable between both                 Optional extra     1.4 kg    190x85x210L

     1m DC 8 mm ring       SIB24300

24V 600 watt 

T

win sockets               interchangeable between both                 Optional extra     2.2 kg    190x85x250L

     1m DC 8 mm ring       SIB24600

24V 1000 watt 

T

win sockets             interchangeable between both                 Optional extra     2.0 kg    190x85x300L

     1m DC 8 mm ring       SIB241000

24V 1600 watt 

T

win sockets             interchangeable between both                 Optional extra     3.6 kg    190x85x300L

     8 mm connection        SIB241600

12V 1000 watt with RCD                                      Neutral earth bonded            Optional extra     2.0 kg    190x85x300L

     1m DC 8 mm ring       SIBR121000

12V 1600 watt with RCD                                      Neutral earth bonded            Optional extra     3.6 kg    190x85x300L

     8 mm connection        SIBR121600

24V 1000 watt with RCD                                     Neutral earth bonded             Optional extra     2.0 kg    190x85x300L

     1m DC 8 mm ring       SIBR241000

24V 1600 watt with RCD                                     Neutral earth bonded             Optional extra     3.6 kg    190x85x300L

     8 mm connection        SIBR241600

Remote control ( 

fits all the above models

 )                                                                                              90x60x20               10 meter                SWR

Pre-fitted

and wired

RCD option

with 1 meter

 AC cable

RoHS

compliant

Pure

sine wave

output

Optional remote

with 10 metres cable 

Range 300-1600 watt 12 & 24v 

Rating Continuous

Содержание Portable Battery Charger B121

Страница 1: ...e beginning of this manual before setup or use of this product Warning do not attempt to charge non rechargeable batteries SPECIFICATIONS PARAMETERS Simple specification Input voltage 220 240VAC 50 60...

Страница 2: ...rotection circuits 1 Connect the battery charger to your battery ensuring the battery voltage is within the voltage ability of the unit i e 12V battery Connect the charger to the 230V AC power ensure...

Страница 3: ...n k nnen Um das Risiko von defekten Batterien zu minimieren hantieren Sie nicht mit metallischen Werkzeugen oder hnlichem in der N he der Batterien Beim Laden stellen Sie das Ladeger t NICHT direkt in...

Страница 4: ...Sie das Ladeger t mit den Batterien Achten Sie auf die korrekte Verbindung ROT POSITIV SCHWARZ NEGATIV 2 Verbinden Sie das Ladeger t mit der 230V Steckdose Achten Sie auch hier darauf dass alles trock...

Страница 5: ...la charge Lire toutes les recommandations de s curit avant d utilser ce produit Avertissement n essayez surtout pas de recharger une batterie non rechargeable PARAMETRES DU CHARGEUR Tension entr e 22...

Страница 6: ...bilit s du chargeur 6V ou 12V Connecter le chargeur la source de courant alternatif 220V assurer vous que l environnement est sec qu aucune trace d eau ne puisse causer un choc lectrique Connecter le...

Страница 7: ...oad Digital battery tester Size mm Weight Part number 280 L x 100 W x 120 D 630mm cable handle to end of clamps 1 1 kg DBT125 Pure Sine wave inverters with USB and RCD version Pro Power SB R Pure Sine...

Страница 8: ...tection User friendly screen LED displays charging status and error Overheat protection short circuit protection reverse polarity protection input low voltage and over voltage protection Charges for c...

Отзывы: