AC Input online, battery charger active
Power save OFF, inverter ON, charger OFF
Charger ON, fast charge mode (Flashing)
Charger ON, float charge mode
Unit over temperature trip
Inverter overload trip
Power save ON, inverter ON, charger OFF
Aux 12V output charger active
Aux 24V output charger active
WARNING- High Voltage cover plate side.
Do not remove unless qualified to do so.
To avoid electric shock,
disconnect AC power & DC battery power
before doing any work on this product
WARNING- Low Voltage high current cover plate side.
Do not open or remove any cover plates unless qualified
to do so. Read and fully understand all operation and
installation instructions regarding this product before
proceeding to install or use this product.
Pro Combi S+1600
www.sterling-power.com www.sterling-power-usa.com
Designed and developed in England. Made in Taiwan
1
2
3
4
5
6
7
8
9
LED Infor Specification
LED Indicator information panel
Multi function thermal fault
Beeper / audible noise continuous
Beeper / audible noise beep every 5 seconds
REMOTE CONTROL LEDs
Constant current charge
Constant voltage charge
Float
Standby
Inverter on
Power saver on
Low input voltage
Battery High voltage
Over load ( Inverter mode)
Over load (Line mode)
Over temp (inverter mode)
Over temp (Line mode)
Over charge
Fan Lock
Battery high V
Inverter mode overload
Line mode overload
Over temperature
Back voltage
F = Flash
F
Power saver
auto mode
Power saver
off
Charge
only
on=
Charge on
Flash =
Charge only
Inverter
(Inverter on )
Alarm
(alarms on box)
1
2
3
Combined pure sine wave inverter and battery charger
Pro Combi S Plus
AC Input online, battery charger active
Power save OFF, inverter ON, charger OFF
Charger ON, fast charge mode (Flashing)
Charger ON, float charge mode
Unit over temperature trip
Inverter overload trip
Power save ON, inverter ON, charger OFF
Aux 12V output charger active
Aux 24V output charger active
F
Sticker information
1)
AC Input online, battery charger active
2)
Power save OFF, inverter ON, charger OFF
3)
Charger ON, fast charge mode (Flashing)
4)
Charger ON, float charge mode
5)
Unit over temperature trip
6)
Inverter overload trip
7)
Power save ON, inverter ON, charger OFF
8)
Aux 12V output charger active
9)
Aux 24V output charger active
- 230V or 110V AC applied to unit and charger is on.
- Power save is off, 0.9A quiescent current, charger not running.
- Charger in the initial stages of the charging cycle.
- Charger in the last stage of the charging cycle (float mode).
- Unit has tripped due to high internal temperature.
- Inverter has been over loaded, your appliance is too highly rated for the Combi.
- Power save is off, 0.4A quiescent current, charger not running. Any device <20W shall not work.
- 12V auxiliary charging module, if installed, shall light up to inform you that it is operational.
- 12V auxiliary charging module, if installed, shall light up to inform you that it is operational.
LED Alarm + Fault finding