IN
OUT
Engine
Starter
motor
primary/starter battery
Alternator
Starter motor
solenoid
secondary/ Domestic battery
Battery Charger
Combi inverter
Solar
Wind
D
ST
CF
G
NE
G
REMOTE
IGNITION KEY
STARTER
Suggested wiring for:
Bidirectional Charging
+
+
+
IN
OUT
Engine
Starter
motor
primary/starter battery
Alternator
Starter motor
solenoid
ST
D
F
C
G
NE
G
REMOTE
Suggested Wiring for:
Engine starter protect
Connect to
Product/system
running from engine
starter battery ie
Inverter
Fridge
TV
Emergency lights
Tail Lift
Power tools
Charging systems
Etc Etc
+
+
+
IN
OUT
secondary/ Domestic battery
D
ST
CF
G
NE
G
REMOTE
Suggested wiring for:
Battery Protection relay
Connect to
Product/system
running from engine
starter battery ie
Small Inverter, Fridge
TV, Emergency lights
Tail Lift, Power tools
Charging systems,
Lights etc etc
All wires connected directly to a battery should be fused in accordance the the current flow
All wires connected directly to a battery should be fused in accordance the the current flow
All wires connected directly to a battery should be fused in accordance to the current flow
Large inverters and other
equipment may already
have low voltage trips
built into their circuits.
So, no need to feed them
through the
Battery Protect system
to
negative
Side profile
Magnetic swipe area
the magnetic reed switch
is behind the plastic case in
this area
+
+
+
IN
OUT
ST
D
G
CF
NE
G
REMOTE
+
+
+
IN
OUT
ST
D
CF
G
N
G
E
REMOTE
Add small
link wire to
access
config program,
remove
after config.
To adjust
preset
voltage
settings
you must
access the
config
setting
Fig 3
Fig 4
Fig 5
Fig 6
Fig 7
Flashes Volts Flashes Volts Flashes Volts
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
10.0
10.1
10.2
10.3
10.4
10.5
10.6
10.7
10.8
10.9
11.0
11.1
11.2
11.3
11.4
11.5
11.6
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
11.7
11.8
11.9
12.0
12.1
12.2
12.3
12.4
12.5
12.6
12.7
12.8
12.9
13.0
13.1
13.2
13.3
Voltage Configuration Table
for Green (ON) & Red (OFF) flashing LEDs
for 24 v divide by 2
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
13.4
13.5
13.6
13.7
13.8
13.9
14.0
14.1
14.2
14.3
14.4
14.5
14.6
14.7
14.8
14.9
15.0
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
F
u
s
e
F
u
se
s:
A
ll
ca
b
le
s
g
o
in
g
t
o
a
b
at
te
ry
b
an
k
m
u
st
b
e
fu
se
s
as
c
lo
se
t
o
t
h
e
b
at
te
ry
a
s
p
o
ss
ib
le
, t
h
e
re
co
m
m
en
d
at
io
n
is
w
it
h
in
1
70
m
m
o
r
7
in
ch
es
o
ff
t
h
e
b
at
te
ry
. S
ig
n
al
w
ir
e
fu
se
s
sh
o
u
ld
b
e
ab
o
u
t
3
am
p
s,
m
ai
n
f
u
se
s
sh
o
u
ld
b
e
ab
o
u
t
30
%
h
ig
h
er
t
h
an
t
h
e
ra
ti
n
g
o
f
th
e
p
ro
d
u
ct
, i
e
if
t
h
e
re
la
y
is
8
0
am
p
s
th
en
a
b
o
u
t
a
10
0
am
p
f
u
se
w
o
u
ld
b
e
su
it
ab
le
.
Table 1