Sterling Power Products DAI-1500C-12 Series Скачать руководство пользователя страница 6

-

3

Sterling reserve the right with some models to supply an accredited installer with 
replacement parts, this may allow the unit to become operable much quicker. In 
this case 

Sterling

 are not responsible for any costs of the installer’s time or 

traveling expenses. Replacement parts are sent at 

Sterling's

 discretion. 

Sterling will in no way be held responsible for any losses incurred  
due to the malfunctioning or failure of a product. 
Suitably qualified personnel must carry out wiring, failure to do so will void   
warranty. 
If you have any questions about this warranty please do not hesitate   
to contact us. 
 

Caution: 

Even when a unit has been completely disconnected, there can   

Still be deadly voltages present at the OUTPUT. To remove these voltages you  
must switch the unit    ON with the ON/OFF switch. After one minute the   
electronics are discharged and any work can now be safely carried out. 

 

Caution:

 In normal use lead-acid and lead-gel batteries give out explosive gases.   

Never smoke or allow a spark or flame in the vicinity of batteries. The batteries   
must always be stored or placed in a well ventilated area, they should be placed in   
such a way that there is no danger of short circuiting through carelessness. Never  
charge frozen batteries. 
This unit is not to be used or sold for life support equipment or applications. 

 

B.1 Special Precautions 

While working on batteries there should always be a second person close to you or 
within your voice range, in case help is needed. 
Plenty of fresh water and soap must be ready at hand so that in case of acid 
coming in contact with skin, eyes and clothes, the areas in question can be 
thoroughly washed. 
If acid enters the eyes, you must thoroughly wash the eyes with cold running water 
for at least 15 minutes. It is recommended that you immediately consult a medical 
doctor. 
Baking powder neutralizes battery acid electrolyte. Always keep some at hand. 
Special care must be taken when working with metal tools near or on the batteries. 
With tools such as screwdrivers, spanners etc. short-circuits can result. Sparks 
produced by the short-circuit can cause an explosion. 
When working on batteries all personal metal items such as rings, necklaces and 
bracelets must be removed. Batteries are so powerful that short-circuit with these 
items can melt them and thus cause severe burns. Always follow the battery 
manufacturers instructions. 

Under certain conditions this unit or a connected generator can start 
automatically. While working on an electrical installation you must ensure that 
these appliances are disconnected before commencing any work. 

Содержание DAI-1500C-12 Series

Страница 1: ...BINED PURE SINE WAVE INVERTER UPS BATTERY CHARGER SOLAR SHORE USER MANUAL Sterling Power Products England Tel 01905 453999 Fax 01905 458836 www sterling power com help sterling power com STERLING POWE...

Страница 2: ...2 C Introduction 4 D Installation 8 E Operation 11 F Disabling Functions 17 G Charger Information 19 H n a I Auxiliary Contacts 21 J The Remote control unit 21 K n a L Programming Aux Contacts AUX1 AU...

Страница 3: ...tion 2 High surge capacity and soft start design for heavy inductive loads such as air conditioning Load detection system for power saving mode Extremely high efficiency Battery Charger The 3 in 1 ser...

Страница 4: ...3000C 12xx DAI 1500C 24xx DAI 1500C 24xx Temperature BTS A 15 m Remote controller RCC A 03 3m RCC A 15 15m Any personnel who install the unit and or works with it must be fully familiar with the cont...

Страница 5: ...consumer rights under local trade practices act This warranty does not extend to products which have been opened altered or repaired by persons other than authorized by Sterling or to products which b...

Страница 6: ...through carelessness Never charge frozen batteries This unit is not to be used or sold for life support equipment or applications B 1 Special Precautions While working on batteries there should always...

Страница 7: ...inal power of the Combi The inverter is protected against overload and short circuit A power stage with the latest MOS FET power transistors a toroidal transformer and a fast regulating system make up...

Страница 8: ...that the batteries are charged correctly With the unit batteries can be charged with a generator and with the solar modules at the same time The charging of batteries with both energy sources is carri...

Страница 9: ...6 C 2 1 Parallel Connection C 2 2 Series Connection...

Страница 10: ...7 C 2 3 Parallel Series Connection...

Страница 11: ...ombi is designed in such a way that it will work most efficiently when mounted vertically In mobile installation it is important to keep vibrations to a minimum D 2 Rear Panel Connections A Battery Ba...

Страница 12: ...it to charge the capacitors This is another reason to install a battery fuse circuit breaker For this reason follow strictly the safety measures described in this manual DO NOT INSERT THE BATTERY FUSE...

Страница 13: ...D 3 5 Connection to Aux1 AUX2 On these three terminals is a potential free change over contact capable of switching a maximum current and voltage of 16A 250V ac The multi display on the front of Combi...

Страница 14: ...10 PB3 PB2 11 2 1 3 4 E 2 Push buttons Push buttons Name Description PB1 RUN STOP RUN STOP key PB2 FUNC k Operation mode select key PB3 AUX1 Auxiliary contract aux1 aux2 Manual Active change And Funct...

Страница 15: ...ect or 2 Day or Night cloudy day 4 SOLAR CHARGER Solar charger is working Solar charger is disabled 5 AC OUT There is voltage at the AC OUT terminal No voltage at the AC OUT terminal 6 INVERTER Green...

Страница 16: ...onitor 9 6 Indicator of error message 12 POWER MONITOR Displays the value of the output power in of max continuous power in Inverter Mode and the charge current in Amps in Charger Mode In this mode th...

Страница 17: ...change For example if you wish to switch the power saver function off you find that the power saver function is attached to function 2 and that selection means off To select this desired option go to...

Страница 18: ...Overload If the unit is overloaded for too long or too heavily it switches off The Multi display will show and the RUN STOP LED will RED Blink After approximately 10 seconds the Inverter switches on a...

Страница 19: ...ns to 12 1V resp 24 2V the inverter switches ON automatically One minute before the Inverter switches OFF due to low voltage a buzzer will be heard The low voltage is set to 11 8V resp 23 6V These set...

Страница 20: ...ilities shown in the following diagram In programming mode the display only shows the different types of program with the Charger Transfer and Inverter functions To change the type of programming pres...

Страница 21: ...ed This is factory setting The inverter ins disabled Only the Bypass switch and charger will work normally Charger and Bypass switch are disabled The inverter will work continuously even if there is a...

Страница 22: ...y the AC load the less power is given to the charger Priority for the AC Loads When power sharing is used the red 200 LED on the power monitor is lit to show that the battery charging is being limited...

Страница 23: ...m the grid or a generator the voltage and quality of the power running the AC load will be the same as that coming from the grid or generator The unit cannot modify the incoming AC supply G 3 The sola...

Страница 24: ...e control unit As an option a Remote control unit can be connected to the unit All operating controls and displays are available on the Remote control unit The Remote control is supplied with a 3m lon...

Страница 25: ...d stops when it has reached the highest programmed condition through charging L 1 2 2 Auxiliary Contact as Twilight Switch With solar charger option The Auxiliary Contact can also be used as a twiligh...

Страница 26: ...stem Thoroughly clean and check all battery connections within the battery bank and to the unit Ensure all connections to the unit are tight Ensure the vents at the top and bottom of the unit are clea...

Страница 27: ...ltage 265 Vac 350 V peak Minimum input voltage Adjustable 150 230Vac Input Frequency range 45 63Hz Charging current adjustable 0 50A 0 35A 100A 0 70A Setting of AC INPUT current POWER SHARING 0 to 15A...

Отзывы: