PRODUCT INFORMATION
Automatic Mode (Default)
This mode is the simplest way to install
the BB1240, however, not the most
effective if you are using this BB on a
modern vehicle that has regenerative
braking (Euro 6 engine or newer).
To activate the BB, you require 13.5V+
on the input terminal. You shall
achieve this voltage by charging up
your input battery (starter battery) with
an alternator (for example).
When the input voltage drops below
12.8V (when you turn your engine off),
the BB shall turn off and go to sleep.
Charge control modes - how to get the BB1240 to turn on and begin charging
CHARGING MODES
10
STERLING
POWER
SHAR
E
V
SHAR
EV
SHAR
E
EV
SHAR
E
V
12V
ign
alarm
GND
50A
fuse
50A
fuse
Alternator
~12V ignition signal
12V
ign
alarm
GND
50A
fuse
50A
fuse
Alternator
12V
ign
alarm
GND
50A
fuse
50A
fuse
Alternator
13.5V+ on
<12.8V off
11V+
Input / starter
battery 12V
Output
battery 12V
Input / starter
battery 12V
Output
battery 12V
Input / starter
battery 12V
Output
battery 12V
Ignition feed Mode
(requires 12V signal feed)
In this mode you control the BB based
on an ignition signal. Essentially when
you are running your engine the signal
is ~12V and BB works. When you turn
your engine off - signal turns to 0V - the
BB turns off.
The BB also requires 11.0V+ on the
input battery. If starter battery is lower
than this w/ live ignition, BB will not
work.
WARNING
, if ignition is live, but
engine not running,
flat starter
battery!
Vibration sense
Switch position ON.
This mode requires the BB to detect 2
vibration events in order for it to turn on
and charge. For example, turning an
engine on shall provide sufficient
vibration to get the BB to begin
charging.
This mode essentially acts like an
ignition signal and is designed for
installers to do away with having to run
an ignition feed.
WARNING, if vibration signal activates
BB, shall drag starter battery voltage
to below 11V. Possible flat starter
battery! The BB does monitor the input
battery and shall turn off after 2
minutes if the voltage does not climb
up.
on off
11V+
on off
select switch position ‘on’ at
anytime to engage vibration
mode.
By applying a live signal to the ignition connector you put the BB into ignition dependent
mode. The BB shall NOT work unless it has a live ignition signal - even if you remove the
ignition feed cable and provide 13.5V+ onto the input terminal.
To reset the BB back to Automatic Mode, ensure BB is on -
I) Remove ignition cable from ign connector.
II) Press and hold SETUP button for around 15 seconds until the 3 LED battery
types flash at the same time.
III) Release button and charger reverts to Automatic Mode.
10mm2 / 8AWG cable
10mm2 / 8AWG cable
common negative
10mm2 / 8AWG cable
10mm2 / 8AWG cable
common negative
10mm2 / 8AWG cable
10mm2 / 8AWG cable
common negative
Input voltage
Charger on - 13.5 -> 16V
Charger off - <12.8V
Input v ign feed.
Charger on - 11V -> 16V
Charger off - <10V
Input v vib. sense.
Charger on - 11V -> 16V
Charger off - <10V
Содержание BB1240